Biomechanical Comparison of Krackow Locking Stitch Versus Nonlocking Loop Stitch With Varying Number of Throws

Author:

Hahn Joseph Minsoo1,İnceoğlu Serkan1,Wongworawat Montri Daniel1

Affiliation:

1. Department of Orthopaedic Surgery, Loma Linda University, Loma Linda, California, USA

Abstract

Background: Common suture configuration techniques used for ligament and tendon grafts and repair are the Krackow locking stitch and a nonlocking loop stitch, such as a whipstitch. Clinically, the preferences of orthopaedic surgeons vary. Hypothesis: The Krackow locking stitch and the nonlocking whipstitch, with varying suture loops, produce different biomechanical and physical effects on the tendon end. Study Design: Controlled laboratory study. Methods: A total of 52 fresh-frozen porcine flexor digitorum tendons were used and assigned into 10 groups. Two stitch configurations (Krackow stitch [K] and whipstitch [W]) with varying number of loops (2 throws, n = 6; 4 throws, n = 5; 6 throws, n = 5; 8 throws, n = 5; 10 throws, n = 5) were tested. No. 2 FiberWire was used. Each sample was preloaded to 5 N and then cyclically loaded for 200 cycles to 200 N at 1 Hz, and then the tendon-suture construct was analyzed for gap formation, tendon elongation, and tendon end width. Next, each tendon was loaded to failure, and ultimate strength and mode of failure were recorded. Data were evaluated with 2-way analysis of variance. Results: For gap formation, the Krackow stitch produced less gap compared with the whipstitch (15.2 ± 4.0 mm [K] vs 18.9 ± 6.8 mm [W]; P = .012). Gap formation was larger when the number of loops increased from 2 to ≥6 ( P = .015). For elongation, the Krackow technique increased the tendon length after cyclic loading. In contrast, the whipstitch was noted to shorten the length of the tendon (1.17 ± 0.97 mm [K] vs −0.14 ± 1.13 mm [W]; P < .001). For tendon end width, the Krackow better preserved the transverse width (–0.64 ± 0.81 mm [K] vs −1.39 ± 0.64 mm [W]; P = .001). Both stitch types had similar ultimate strength (322.1 ± 20.3 N [K] vs 319.7 ± 20.4 N [W]; P = .676) and modes of failure (all by suture breakage; therefore, no statistical calculation was performed). There was no statistical difference in tendon elongation, width, failure load, or mode regardless of the number of throws. Conclusion/Clinical Relevance: Given the finding that the Krackow suture had less gap formation and better preservation of tendon architecture (length and width) compared with the whipstitch, coupled with the finding that ultimate strength is similar with both types of sutures, the Krackow stitch is recommended for tendon reconstruction when these parameters are important.

Publisher

SAGE Publications

Subject

Physical Therapy, Sports Therapy and Rehabilitation,Orthopedics and Sports Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3