Biomechanical Stability of Lateral Ulnar Collateral Ligament Reconstruction and Repair of the Elbow: The Role of Ligament Bracing on Gap Formation and Stabilization

Author:

Bachmaier Samuel1,Wijdicks Coen A.1,Verma Nikhil N.2,Higgins Laurence D.1,Greiner Stefan3

Affiliation:

1. Arthrex Department of Research and Development, Munich, Germany

2. Rush University Medical Center, Chicago, Illinois, USA

3. Porthopaedicum, Regensburg, Germany

Abstract

Background: Augmented (internal braced) lateral ulnar collateral ligament (LUCL) repair has been biomechanically compared with reconstruction techniques in the elbow. However, LUCL repair alone has not yet been compared with augmented repair and reconstruction techniques. Hypothesis: Internal bracing of LUCL repair would improve time-zero stabilization regarding gap formation, stiffness, and residual torque as compared with repair alone and reconstruction techniques to restore native elbow stability. Study Design: Controlled laboratory study. Methods: Overall, 24 cadaveric elbows were used for either internal braced LUCL repair (Repair-IB) or single- and double-strand ligament reconstruction with triceps (Recon-TR) and palmaris longus tendon graft (Recon-PL), respectively. Laxity testing in external rotation was consecutively performed at 90° of elbow flexion on the intact, dissected, and repaired conditions and with the previously assigned techniques. First, intact elbows were loaded to 7.0-N·m external torque to evaluate time-zero ligament rotations at 2.5, 4.0, 5.5, and 7.0 N·m. Rotation-controlled cycling was performed (total of 1000 cycles) for each surgical condition. Gapping, stiffness, and residual torque were analyzed. Finally, these and 8 additional intact elbows underwent torque-to-failure testing (30 deg/min). Results: The dissected state showed the highest gap formation and lowest peak torques ( P < .001). While gap formation of Repair-IB ( P < .021) was significantly lower than that of repair without internal bracing at all rotation levels, gaps of Recon-PL were similar to and Recon-TR were significantly higher than those of Repair-IB except for the highest torsion level. Residual peak torques at specific rotation angles between native state and Recon-TR (α2.5), Recon-PL (α4.0), and Repair-IB (α5.5) were similar; all other comparisons were significantly different ( P < .027). Torsional stiffness of Repair-IB was significantly higher at all rotation angles measured. Analysis of covariance showed significantly less gap formation over residual peak torques for Repair-IB ( P < .001) as compared with all other groups. The native state failure load was significantly higher than Recon-PL and Recon-TR failure loads, with similar stiffness to all other groups. Conclusion: Repair-IB and Recon-PL of the LUCL showed increased rotational stiffness relative to the intact elbow for restoring posterolateral stability to the native state in a cadaveric model. Recon-TR demonstrated lower residual peak torques but provided near-native rotational stiffness. Clinical Relevance: Internal bracing of LUCL repair may reduce suture-tearing effects through tissue and provide sufficient stabilization for healing throughout accelerated and reliable recovery without the need for a tendon graft.

Funder

arthrex

Publisher

SAGE Publications

Subject

Physical Therapy, Sports Therapy and Rehabilitation,Orthopedics and Sports Medicine

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3