Affiliation:
1. Department of Orthopaedics, Division of Sports Medicine, University of Florida, Gainesville, Florida
Abstract
Radiographic increase in the size of tibial and femoral tunnels has been observed. This retrospective study compared tibial tunnel diameter in 56 autograft and 87 allograft patellar tendon bone-tendon-bone anterior cru ciate ligament replacements whose observed tunnel changes were correlated with clinical results at 1 year postoperatively. Tibial tunnel sclerotic margins were measured approximately 1 cm below the joint line. Ex act tunnel dimension was calculated by using a mag nification factor determined by the interference screw of known diameter within the same tunnel. Average al lograft tunnel enlargement was 1.2 mm (-2.5 to 6.0) compared with the autograft tunnel enlargement of 0.26 mm (-2.5 to 2.7); the difference was significant (P> 0.0002). No significant difference was seen in KT-1000 arthrometer measurements between autograft or allograft groups, and no correlation was seen be tween increased tunnel size and clinical outcome as determined by the modified Hughston knee evaluation system. Tunnel measurement reproducibility was con firmed by independent repeated measurements. The significance of this tunnel enlargement is unknown and does not appear to adversely affect clinical outcome of allograft utilization. Possible explanations include an immune response with resorption, stress shielding proximal to the interference screw resulting in resorp tion, or an inflammatory response by synovium in the tunnel.
Subject
Physical Therapy, Sports Therapy and Rehabilitation,Orthopedics and Sports Medicine
Cited by
254 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献