The Anterolateral Ligament

Author:

Kennedy Mitchell I.1,Claes Steven23,Fuso Fernando Augusto Freitas1,Williams Brady T.1,Goldsmith Mary T.1,Turnbull Travis Lee1,Wijdicks Coen A.1,LaPrade Robert F.14

Affiliation:

1. Steadman Philippon Research Institute, Vail, Colorado, USA

2. AZH Hospital, Herentals, Belgium

3. University Hospitals, Leuven, Belgium

4. The Steadman Clinic, Vail, Colorado, USA

Abstract

Background: Recent publications have described significant variability in the femoral attachment and overall anatomy of the anterolateral ligament (ALL). Additionally, there is a paucity of data describing its structural properties. Purpose: Quantitative data characterizing the anatomic and radiographic locations and the structural properties of the ALL may be used to guide graft selection and placement and to facilitate the future development of an evidence-based approach to ALL reconstructions. Study Design: Descriptive laboratory study. Methods: Identification of the ALL was performed by a combined outside-in and inside-out anatomic dissection of 15 nonpaired fresh-frozen cadaveric knees. Quantitative anatomic relationships were calculated using a 3-dimensional coordinate measuring device. Measurements on anteroposterior (AP) and lateral radiographs were obtained by use of a picture archiving and communications system program. Structural properties were characterized during a single pull-to-failure test using a tensile testing machine. All anatomic, radiographic, and biomechanical measurements were reported as mean values and 95% CIs. Results: The ALL was identified as a thickening of the lateral capsule coming under tension with an applied internal rotation at 30° of flexion. Its femoral attachment was located 4.7 mm (95% CI, 3.5-5.9 mm) posterior and proximal to the fibular collateral ligament attachment and coursed anterodistally to its anterolateral tibial attachment approximately midway between the center of the Gerdy tubercle and the anterior margin of the fibular head; the tibial attachment was located 24.7 mm (95% CI, 23.3-26.2 mm) and 26.1 mm (95% CI, 23.9-28.3 mm) from each structure, respectively. On the AP radiographic view, the ALL originated on the femur 22.3 mm (95% CI, 20.7-23.9 mm) proximal to the joint line and inserted on the tibia 13.1 mm (95% CI, 12.3-13.9 mm) distal to the lateral tibial plateau. On the lateral view, the femoral attachment was 8.4 mm (95% CI, 6.8-10.0 mm) posterior and proximal to the lateral epicondyle. The tibial attachment was 19.0 mm (95% CI, 17.1-20.9 mm) posterior and superior to the center of the Gerdy tubercle. The mean maximum load was 175 N (95% CI, 139-211 N) and the stiffness was 20 N/mm (95% CI, 16-25 N/mm). Failure occurred by 4 distinct mechanisms: ligamentous tear at the femoral (n = 4) or tibial (n = 1) attachment, midsubstance tear (n = 4), and bony avulsion of the tibial attachment (Segond fracture; n = 6). Conclusion: Defined ALL attachment locations can be reproducibly identified with intraoperative landmarks or radiographs. The biomechanical analysis suggests that most traditional soft tissue grafts are sufficient for ALL reconstruction. Clinical Relevance: The ALL was consistently found in all knees. Segond fractures appear to occur primarily from the avulsion of the ALL.

Publisher

SAGE Publications

Subject

Physical Therapy, Sports Therapy and Rehabilitation,Orthopedics and Sports Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3