Safe Drilling Paths in the Distal Femoral Epiphysis for Pediatric Medial Patellofemoral Ligament Reconstruction

Author:

Nguyen Cynthia V.1,Farrow Lutul D.2,Liu Raymond W.1,Gilmore Allison1

Affiliation:

1. Division of Pediatric Orthopaedic Surgery, Case Western Reserve University, Rainbow Babies and Children’s Hospital, Cleveland, Ohio, USA

2. Orthopaedic and Rheumatologic Institute, Cleveland Clinic Foundation, Cleveland, Ohio, USA

Abstract

Background: Anatomic surgical reconstruction of the medial patellofemoral ligament (MPFL) has been popularized for the treatment of recurrent patellar instability in the skeletally immature population. Previous anatomic studies have found that the femoral attachment point of the MPFL is very close to the distal femoral physis. Purpose: To establish the safe angles for drilling the distal femoral epiphysis for MPFL graft placement. Study Design: Descriptive laboratory study. Methods: A total of 23 cadaveric distal femoral epiphyses were scanned into high-resolution 3-dimensional images. Using computer-aided design, we identified and marked the femoral insertion site of the MPFL. Cylinders 8 mm in diameter were placed at varying angles to simulate the drill paths for placement of 6-mm interference screws with a 1-mm buffer. The distance from the MPFL footprint to where the tunnel first violated the physis, the intercondylar notch, or the distal cartilage was measured. We recorded the percentage of tunnels that caused violations before reaching 20 mm, the shortest length of a typical femoral tunnel socket. Results: Measurements indicated that 41% of tunnels angled distally less than 10° violated the physis, 40% of tunnels angled distally more than 10° but anteriorly less than 10° violated the notch, and 27% of tunnels angled distally and anteriorly more than 20° violated the distal femoral cartilage. At least 90% of the tunnels were safe at 20 mm when the drill was angled between 15° and 20° both anteriorly and distally. Conclusion: Because of the anatomy of the distal femoral physis, drilling into the epiphysis from the MPFL attachment site at improper trajectories risks damage to sensitive structures. Angling the drill to an acceptable degree distally and anteriorly leads to less risk to the physis and notch, respectively, but angling too much leads to risk to the distal femoral cartilage. Small variations in the sagittal plane were better tolerated than variations in the coronal plane, so we recommend that more attention be paid to the radiographic anteroposterior view intraoperatively. It is safest to angle the drill distally and anteriorly approximately 15° to 20° in each plane from the MPFL attachment site. Clinical Relevance: During drilling into the distal femoral epiphysis at the MPFL origin in skeletally immature patients, angling the drill appropriately 15° to 20° both distally and anteriorly minimizes damage to the physis, notch, and distal femoral cartilage.

Publisher

SAGE Publications

Subject

Physical Therapy, Sports Therapy and Rehabilitation,Orthopedics and Sports Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3