Biomechanical Assessment of Bicortical Suspension Device Fixation for Proximal Tibiofibular Joint Instability: Single Versus Double Device

Author:

Wang Shangcheng1,Rice Olivia M.1,Habet Nahir A.1,CarlLee Tyler L.2,Duemmler Marc1,Wally Meghan1,Odum Susan1,Moorman Claude T.1

Affiliation:

1. Department of Orthopaedic Surgery, Atrium Health Musculoskeletal Institute, Charlotte, North Carolina, USA

2. University of Arkansas for Medical Sciences, Fayetteville, Arkansas, USA

Abstract

Background: Bicortical suspension device (BCSD) fixation treats proximal tibiofibular joint (PTFJ) instability in both the anterolateral and posteromedial directions. However, biomechanical data are lacking as to whether this technique restores the native stability and strength of the joint. Purpose: To test (1) if BCSD fixation restores the native stability and strength and (2) if using 2 devices is needed. Study Design: Controlled laboratory study. Methods: Sixteen pairs of fresh-frozen cadaveric specimens were obtained. Six pairs were assigned to the control group and 10 matched pairs assigned for transection to model PTFJ and subsequent BCSD fixation (one specimen with 1-device repair and the other with 2-device repair). Joint stability and strength were assessed by translating the fibular head relative to the fixed tibia either anterolaterally or posteromedially. Control specimens received 20 cycles of 0- to 2.5-mm joint displacement tests (subfailure) and then proceeded to load to failure (5 mm). For the experimental group, cyclic tests were repeated after ligament resection and after fixation. Forces and stiffness at 2.5- and 5-mm displacement were recorded for comparisons of joint strength and stability at subfailure and failure loads, respectively. Results: After repair of anterolateral instability, both the single- and double-device fixations successfully restored near-native states, with no significant differences as compared with the intact group for forces at subfailure load ( P = .410) or failure load ( P = .397). Regarding posteromedial instability, single-device repair did not restore forces to the near-native state at subfailure load (intact: 92.9 N vs single: 37.4 N; P = .001) or failure load (intact: 170.7 N vs single: 70.4 N; P = .024). However, the double-device repair successfully restored near-native posteromedial forces at both subfailure load ( P = .066) and failure load ( P = .723). Conclusion: For treatment of the most common form of PTFJ instability (anterolateral), this cadaveric study suggests that 1 BCSD is sufficient to restore stability and strength. The current biomechanical results also suggest that 2 devices are needed for restoring PTFJ posteromedial stability and strength. Using 2 devices addresses both types of instability and provides more PTFJ posteromedial stability. Clinical Relevance: The results suggest that 1 device should be used for treating anterolateral instability and 2 devices used for posteromedial instability based on the biomechanical study.

Funder

Arthrex

Publisher

SAGE Publications

Subject

Physical Therapy, Sports Therapy and Rehabilitation,Orthopedics and Sports Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3