Does Capsular Laxity Lead to Microinstability of the Native Hip?

Author:

Han Shuyang1,Alexander Jerry W.1,Thomas Vijai S.1,Choi Joshua1,Harris Joshua D.2,Doherty David B.3,Jeffers Jonathan R.T.4,Noble Philip C.15

Affiliation:

1. Institute of Orthopedic Research and Education, Houston, Texas, USA

2. Department of Orthopedics and Sports Medicine, Houston Methodist Hospital, Houston, Texas, USA

3. Department of Orthopedic Surgery, McGovern Medical School, Houston, Texas, USA

4. Department of Mechanical Engineering, Imperial College London, London, UK

5. Baylor College of Medicine, Houston, Texas, USA

Abstract

Background: Hip “microinstability” is commonly cited as the cause of symptoms that occur in the presence of translation of the femoral head away from conformity with the acetabular fossa. However, there is still no consistent objective criteria defining its presence and biomechanical basis. One hypothesis is that abnormal motion of the articular surfaces occurs because of capsular laxity, ultimately leading to clinical symptoms. Purpose: To determine the relationship between capsular laxity and abnormal rotation and translation of the hip. Study Design: Controlled laboratory study. Methods: Eight cadaveric hips were dissected down to the capsule and mounted in a customized multiaxial hip activity simulator. Each specimen was loaded with 5 N·m of internal and external rotational torque in full extension and 0°, 30°, 60°, and 90° of flexion. During testing, the relative position and rotation of the femur and the pelvis were monitored in real time with a 6-camera motion analysis system. The testing was repeated after capsular laxity was generated by placing a regular array of incisions (“pie crusting”) in the iliofemoral, pubofemoral, and ischiofemoral ligaments. Joint rotation and femoral head translation were calculated with specimen-specific models. A hip microinstability index was defined as the ratio between the length of the locus of the femoral head center and the radius of the femoral head during rotation from extension to 90° of flexion. Results: In intact hips, the components of femoral head translation were within 0.5 mm in positions close to neutral (<30° of flexion). Capsular modification led to significant increases in internal and external rotation ( P < .01) and in the translation of the femoral head center at different positions ( P < .05). Compared with intact hips, the femoral head was inferiorly displaced during external rotation and anteroinferiorly during internal rotation. The length of the locus of the femoral head center increased from 3.61 ± 1.30 mm to 5.35 ± 1.83 mm for external rotation ( P < .05) and from 6.24 ± 1.48 mm to 8.21 ± 1.42 mm for internal rotation ( P < .01). The correlations between rotational laxity and the total translation of the femoral head were not significant, with coefficients of 0.093 and 0.006 in external and internal rotation, respectively. In addition, the hip microinstability index increased from 0.40 ± 0.08 for intact hips to 0.55 ± 0.09 for modified hips ( P < .01). Conclusion: The native hip approximates a concentric ball-and-socket joint within 30° of flexion; however, beyond 30° of flexion, the femoral head translation reached as high as 4 mm. Capsular laxity leads to microinstability of the hip, as indicated by significantly increased joint rotations and femoral head translations and an abnormal movement path of the femoral head center. However, there was no correlation between rotational laxity and the increase in femoral head translation. Clinical Relevance: Capsular laxity alters normal kinematics (joint rotation and femoral head translation) of the hip, potentially leading to abnormal femoral-acetabular contact and joint degeneration.

Publisher

SAGE Publications

Subject

Physical Therapy, Sports Therapy and Rehabilitation,Orthopedics and Sports Medicine

Cited by 67 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3