Pull-out Strength of Suture Anchor and Torque of Buddy Anchor for an Osteoporotic Humeral Head in Rotator Cuff Repair: Parallel Versus Divergent Insertion

Author:

Do Woo-Sung1,Kim Joo-Hyung1,Lim Joon-Ryul1,Yoon Tae-Hwan1,Chun Yong-Min1

Affiliation:

1. Department of Orthopaedic Surgery, Arthroscopy and Joint Research Institute, Severance Hospital, Yonsei University College of Medicine, Seoul, Korea

Abstract

Background: The buddy anchor technique is useful to reinforce loose anchors in the osteoporotic humeral head during arthroscopic rotator cuff repair. However, theoretical parallel insertion of the buddy anchor to index a loose anchor is challenging in arthroscopy and can widen the entry site and decrease structural integrity. Purpose: To investigate and compare the biomechanical stability between 2 buddy anchor insertion techniques (parallel insertion vs divergent insertion) in the osteoporotic humeral head. Study Design: Controlled laboratory study. Methods: A total of 24 paired fresh-frozen cadaveric shoulders were used, and each pair was randomly assigned to either the parallel insertion group or the divergent insertion group. In the parallel insertion group, the buddy anchor was inserted parallel to the index loose anchor. In the divergent insertion group, the buddy anchor was inserted at a 20° angle in the medial direction to the index loose anchor. The insertion torque of the buddy anchor and ultimate pull-out strength of the index anchor were measured and compared between the 2 groups. Results: The mean maximum insertion torque was significantly higher in the parallel insertion group (16.1 ± 1.8 cN·m) compared with the divergent insertion group (12.0 ± 1.5 cN·m) ( P < .001). The mean ultimate pull-out strength was significantly higher with divergent insertion (192.2 ± 28.6 N) than with parallel insertion (147.7 ± 23.6 N) ( P < .001). Conclusion: For application of the buddy anchor system in the cadaveric osteoporotic humeral bone model, divergent insertion showed better ultimate pull-out strength than conventional parallel insertion, despite inferior maximum insertion torque. Clinical Relevance: The results of this study widen the applicability and accessibility for the buddy anchor system.

Publisher

SAGE Publications

Subject

Physical Therapy, Sports Therapy and Rehabilitation,Orthopedics and Sports Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3