A Biomechanical Analysis of Anterior Bankart Repair Using Suture Anchors

Author:

Nho Shane J.1,Frank Rachel M.1,Van Thiel Geoffrey S.1,Wang Fan Chia12,Wang Vincent M.1,Provencher Matthew T.3,Verma Nikhil N.1

Affiliation:

1. Department of Orthopaedic Surgery, Rush University Medical Center, Chicago, Illinois

2. Department of Bioengineering, University of Illinois at Chicago, Chicago, Illinois

3. Department of Orthopaedic Surgery, Naval Medical Center, San Diego, California

Abstract

Background: Arthroscopic repair of anterior Bankart lesions is typically done with single-loaded suture anchors tied with simple stitch configuration. Hypothesis: The knotless suture anchor will have similar biomechanical properties compared with two types of conventional suture anchors. Study Design: Controlled laboratory study. Methods: Fresh-frozen shoulders were dissected and an anteroinferior Bankart lesion was created. For phase 1, specimens were randomized into either simple stitch (SSA) or knotless suture anchors (KSA) and loaded to failure. For phase 2, specimens were randomized into 1 of 4 repair techniques and cyclically loaded then loaded to failure: (1) SSA, (2) suture anchor with horizontal mattress configuration, (3) double-loaded suture anchor with simple stitch configuration, or (4) KSA. Data recorded included mode of failure, ultimate load to failure, load at 2 mm of displacement, as well as displacement during cyclical loading. Results: For phase 1, the load required to 2 mm displacement of the repair construct was significantly greater in SSA (66.5 ± 21.7 N) than KSA (35.0 ± 12.5 N, P = .02). For phase 2, there was a statistically significant difference in ultimate load to failure among the 4groups, with both the single-loaded suture anchor with simple stitch (184.0 ± 64.5 N), horizontal mattress stitch (189.0 ± 65.3N), and double-loaded suture anchor with simple stitch (216.7 ± 61.7 N) groups having significantly ( P < .05) higher loads than the knotless group (103.9 ± 52.8 N). There was no statistically significant difference ( P > .05) among the 4 groups in displacement after cyclical loading or load at 2 mm of displacement. Conclusion: Both knotless and simple anchor configurations demonstrated similar single loads to failure (without cycling); however, the knotless device required less single load to displace 2 mm. All repair stitches, including simple, horizontal, and double-loaded performed similarly. Clinical Relevance: The findings may suggest that with cyclical loading up to 25 N there is no difference in gapping greater than 2mm, but a macrotraumatic event may demonstrate a difference in fixation during the initial postoperative period. Additional in vivo studies are needed to determine whether these differences affect the integrity of the repair construct and, ultimately, the clinical outcome.

Publisher

SAGE Publications

Subject

Physical Therapy, Sports Therapy and Rehabilitation,Orthopedics and Sports Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3