The Modified Assessment Tool Based on Scapular Y-View for Global Fatty Infiltration in the Supraspinatus Muscle: Correlation, Predictive Performance, and Reliability Analyses

Author:

Xu Junjie1ORCID,Liu Beibei2,Han Kang1ORCID,Ye Zipeng1ORCID,Zhang Xiuyuan1,Qiao Yi1,Jin Yuchen345,Jiang Jia1,Su Wei1ORCID,Li Yuehua2,Zhao Jinzhong1ORCID

Affiliation:

1. Department of Sports Medicine, Shanghai Sixth People’s Hospital Affiliated to Shanghai Jiao Tong University School of Medicine, Shanghai, China

2. Institute of Diagnostic and Interventional Radiology, Shanghai Sixth People’s Hospital Affiliated to Shanghai Jiao Tong University School of Medicine, Shanghai, China

3. Department of Nuclear Medicine, Renji Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China

4. Department of Nuclear Medicine, Shanghai Sixth People’s Hospital Affiliated to Shanghai Jiao Tong University, Shanghai, China

5. Human Oncology and Pathogenesis, Memorial Sloan-Kettering Cancer Center, New York, New York, USA

Abstract

Background: The accurate evaluation of rotator cuff (RC) fatty degeneration after tears is critical for appropriate surgical decision making and prognosis. However, there is currently no reliable and practical tool to reflect the global fatty infiltration (Global-FI) throughout the 3-dimensional (3D) volumetric RC muscles. Purpose: (1) To determine the correlations between 2 modified assessment tools and the Global-FI and their predictive performances and reliabilities for Global-FI prediction, and (2) to compare these predictive parameters with those of the conventional tool using a single scapular Y-view slice. Study Design: Cohort study (diagnosis); Level of evidence, 3. Methods: A total of 49 patients with full-thickness RC tears scheduled to undergo arthroscopic repairs were included, and their surgical shoulders underwent 6-point Dixon magnetic resonance imaging preoperatively. The Global-FI was measured by calculating the 3D-volumetric fat fraction (FF) of the whole supraspinatus muscle through all acquired oblique sagittal slices. As a commonly used radiological landmark, the scapular Y-view was used to evaluate single-plane fatty infiltration (Y-FI) by calculating the FF in 1 slice, defined as the conventional assessment tool. Two modified assessment tools expand the analytic imaging by integrating the FFs from the scapular Y-view slice and its neighboring slices, which were calculated by averaging the FFs of these 3 slices (meanY3-FI) and accumulating local 3D-volumetric FFs from 3 slices (volY3-FI), respectively. The correlations between 3 assessment tools and the Global-FI were analyzed, and the predictive performance for Global-FI prediction using these tools was determined by goodness of fit and agreement. Moreover, the inter- and intraobserver reliabilities of these assessment tools were evaluated. Similar analyses were performed in the small-medium, large, or massive tear subgroups. Results: The Y-FI was significantly higher than the Global-FI in all cases and tear size subgroups, while the 2 modified assessment tools (meanY3-FI and volY3-FI) did not significantly differ from the Global-FI. All assessment tools were significantly correlated with the Global-FI, but the meanY3-FI and volY3-FI showed stronger correlations than the Y-FI, which was also determined in different tear sizes. Moreover, the regression models of the meanY3-FI and volY3-FI showed superior goodness of fit to Y-FI in Global-FI prediction in all cases and subgroups, with larger coefficients of determination ( R2) and smaller root mean square errors. The predicted Global-FI using the regression model of volY3-FI had the best agreement with the measured Global-FI, followed by the meanY3-FI, both showing smaller biases and standard deviation of the percentage difference between predicted- and measured Global-FI than the conventional Y-FI. In addition, the 2 modified assessment tools achieved better interobserver and intraobserver reliabilities than the conventional tool in all cases and subgroups. Conclusion: Two modified assessment tools (meanY3-FI and volY3-FI) were comparable with the Global-FI of the whole supraspinatus muscle, showing stronger correlations with the Global-FI and better predictive performances and reliabilities than the conventional tool (Y-FI). Moreover, the volY3-FI was slightly superior to meanY3-FI in the predictive performance and reliability.

Funder

National Natural Science Foundation of China

Natural Science Foundation of Shanghai

Shanghai Rising-Star Program

Publisher

SAGE Publications

Subject

Physical Therapy, Sports Therapy and Rehabilitation,Orthopedics and Sports Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3