Hip Capsular Closure: A Biomechanical Analysis of Failure Torque

Author:

Chahla Jorge1,Mikula Jacob D.1,Schon Jason M.1,Dean Chase S.1,Dahl Kimi D.1,Menge Travis J.1,Soares Eduardo1,Turnbull Travis Lee1,LaPrade Robert F.12,Philippon Marc J.12

Affiliation:

1. Steadman Philippon Research Institute, Vail, Colorado, USA

2. The Steadman Clinic, Vail, Colorado, USA

Abstract

Background: Hip capsulotomy is routinely performed during arthroscopic surgery to achieve adequate exposure of the joint. Iatrogenic instability can result after hip arthroscopic surgery because of capsular insufficiency, which can be avoided with effective closure of the hip capsule. There is currently no consensus in the literature regarding the optimal quantity of sutures upon capsular closure to achieve maximal stability postoperatively. Purpose/Hypothesis: The purpose of this study was to determine the failure torques of 1-, 2-, and 3-suture constructs for hip capsular closure to resist external rotation and extension after standard anterosuperior interportal capsulotomy (12 to 3 o’clock). Additionally, the degree of external rotation at which the suture constructs failed was recorded. The null hypothesis of this study was that no significant differences with respect to the failure torque would be found between the 3 repair constructs. Study Design: Controlled laboratory study. Methods: Nine pairs (n = 18) of fresh-frozen human cadaveric hemipelvises underwent anterosuperior interportal capsulotomy, which were repaired with 1, 2, or 3 side-to-side sutures. Each hip was secured in a dynamic biaxial testing machine and underwent a cyclic external rotation preconditioning protocol, followed by external rotation to failure. Results: The failure torque of the 1-suture hip capsular closure construct was significantly less than that of the 3-suture construct. The median failure torque for the 1-suture construct was 67.4 N·m (range, 47.4-73.6 N·m). The median failure torque was 85.7 N·m (range, 56.9-99.1 N·m) for the 2-suture construct and 91.7 N·m (range, 74.7-99.0 N·m) for the 3-suture construct. All 3 repair constructs exhibited a median 36° (range, 22°-64°) of external rotation at the failure torque. Conclusion: The most important finding of this study was that the 2- and 3-suture constructs resulted in comparable biomechanical failure torques when external rotation forces were applied to conventional hip capsulotomy in a cadaveric model. The 3-suture construct was significantly stronger than the 1-suture construct; however, there was not a significant difference between the 2- and 3-suture constructs. Additionally, all constructs failed at approximately 36° of external rotation. Clinical Relevance: Re-establishing the native anatomy of the hip capsule after hip arthroscopic surgery has been reported to result in improved outcomes and reduce the risk of iatrogenic instability. Therefore, adequate capsular closure is important to restore proper hip biomechanics, and postoperative precautions limiting external rotation should be utilized to protect the repair.

Publisher

SAGE Publications

Subject

Physical Therapy, Sports Therapy and Rehabilitation,Orthopedics and Sports Medicine

Cited by 48 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3