A Biomechanical Comparison of Initial Fixation Strength of 3 Different Methods of Anterior Cruciate Ligament Soft Tissue Graft Tibial Fixation

Author:

Bartz Reed L.1,Mossoni Kory2,Tyber Jeffrey3,Tokish John4,Gall Kenneth3,Siparsky Patrick N.2

Affiliation:

1. Nebraska Orthopaedics, Lincoln, Nebraska

2. University of Colorado, Boulder, Colorado

3. Georgia Institute of Technology, Atlanta, Georgia

4. United States Air Force Academy, USAFA, Colorado

Abstract

Background Tibial fixation of soft tissue grafts continues to be problematic in the early postoperative period after anterior cruciate ligament reconstruction. Hypothesis No differences exist for resistance to slippage of soft tissue grafts fixed with CentraLoc, Intrafix, or 35-mm bioabsorbable interference screws. Study Design Controlled laboratory study. Methods Bovine tibia and hoof extensor tendons were divided into 3 matched groups with 12 tibia and 12 extensor tendons in each group. Within each group, 6 specimens underwent monotonic loading to failure (1 mm/s), and 6 underwent cyclic loading (10 000 cycles, 125-325 N, 1 Hz). Results No statistically significant differences were noted in mean load to failure or stiffness. The mean load to failure (and stiffness) for the 3 types of fixation were as follows: bioabsorbable interference screw, 631.6 ± 130.1 N (88.17 ± 6.79 N/mm); Intrafix, 644.3 ± 195.2 N (81.65 ± 16.5 N/mm); and CentraLoc, 791.1 ± 72.7 N (77.89 ± 7.07 N/mm). The slippage rates under cyclic loading for the 3 types of fixation were bioabsorbable interference screw, 0.336 ± 0.074 µm/cycle; Intrafix, 27.2 ± 31.6 µm/cycle; and CentraLoc, 0.0355 ± 0.0046 µm/cycle. In this model, CentraLoc proved statistically superior in resistance to cyclic loading compared with the bioabsorbable interference screw (P < .05) and Intrafix (P < .0001). The bioabsorbable interference screw proved statistically superior to Intrafix in resistance to cyclic loading (P < .05). Conclusions In this bovine model, CentraLoc and bioabsorbable interference screws provided superior resistance to cyclic loading compared with Intrafix. Clinical Relevance CentraLoc and bioabsorbable interference screws showed superior resistance to cyclic loading, which may indicate an increased resistance to clinical failure.

Publisher

SAGE Publications

Subject

Physical Therapy, Sports Therapy and Rehabilitation,Orthopedics and Sports Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3