Bioresorbable Pins and Interference Screws for Fixation of Hamstring Tendon Grafts in Anterior Cruciate Ligament Reconstruction Surgery

Author:

Stengel Dirk12,Casper Dirk1,Bauwens Kai1,Ekkernkamp Axel12,Wich Michael1

Affiliation:

1. Center for Clinical Research and the Department of Trauma and Orthopedic Surgery, Unfallkrankenhaus Berlin, Berlin, Germany

2. Department of Trauma and Orthopedic Surgery, University Hospital of Greifswald, Greifswald, Germany

Abstract

Background Biodegradable cross-pins have been shown to provide higher failure loads than do screws for fixation of hamstring tendons under laboratory conditions. Purpose To compare the clinical results of biodegradable pins (RigidFix) and interference screws (BioCryl) for fixation of hamstring grafts in arthroscopically assisted anterior cruciate ligament reconstruction. Study Design Randomized controlled trial; Level of evidence, 1. Methods To test the hypothesis of a difference of 1.0 ± 1.2 mm in anterior knee laxity between the two fixation options, 54 patients were randomly assigned to groups via a block randomization scheme and sealed envelopes. All patients underwent standardized hamstring graft reconstruction and had similar postoperative aftercare by an accelerated rehabilitation protocol. Measures assessed at baseline and after 1 and 2 years of follow-up included (1) the side-to-side difference in anterior laxity (KT-1000 arthrometer), (2) Short Form 36 physical and mental component scores, and (3) the International Knee Documentation Committee form scores. Results After 1 and 2 years, 26 and 21 patients in the BioCryl group and 28 and 24 patients in the RigidFix group were available for follow-up examination. No significant difference was noted in instrumented anterior translation between BioCryl and RigidFix fixation: 1 year, 0.11 (95% CI, —0.60 to 0.82; P = .7537); 2 years, 0.33 (95% CI, —0.43 to 1.08 mm; P = .3849). Also, there were no significant differences in the mean physical and mental component scores and International Knee Documentation Committee form scores and in overall complication and surgical revision rates. A pin dislocation was classified as the sole procedure-specific serious adverse event. Conclusion Bioresorbable pins do not provide better clinical results than do resorbable interference screws for hamstring graft fixation in anterior cruciate ligament reconstruction surgery.

Publisher

SAGE Publications

Subject

Physical Therapy, Sports Therapy and Rehabilitation,Orthopedics and Sports Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3