Abstract

Background There is a need for a patient-relevant instrument to evaluate outcome after treatment in patients with a total Achilles tendon rupture. Purpose To develop and validate a new patient-reported instrument for measuring outcome after treatment for total Achilles tendon rupture. Study Design Cohort study (diagnosis); Level of evidence, 1. Methods Development of this instrument consisted of item generation and test construction, item reduction, validation, evaluation of structure and internal consistency, test-retest, and test for responsiveness. The final version, the Achilles tendon Total Rupture Score (ATRS), was tested for validity, structure, and internal consistency (Cronbach's alpha) on 82 patients and 52 healthy persons. A correlation analysis was performed of the ATRS with the 2 validated foot/ankle/Achilles tendon scores, the Foot and Ankle Outcome Score (FAOS) and the Swedish version of the Victorian Institute of Sports Assessment-Achilles questionnaire (VISA-A-S). Structure was evaluated with factor analysis. Test-retest reliability was evaluated on 43 patients. The ATRS responsiveness was tested on 43 patients by calculating the effect size. Results The total score for the patients ranged from 17 to 100 with a mean (median) of 77 (85) and a standard deviation (interquartile range) of 21.4 (23). A significantly (P < .0001) higher total score was found for the healthy subjects, ranging from 94 to 100 with a mean (median) of 99.8 (100) and a standard deviation (interquartile range) of 1.1 (0). The ATRS correlated significantly (P < .01) with all subscales of the FAOS (r = 0.60-0.84) and the VISA-A-S (r = 0.78). The factor analysis gave 1 factor of importance. The internal consistency was 0.96 as measured with Cronbach's alpha. The test-retest produced an intraclass correlation coefficient of 0.98. The tests for responsiveness showed an effect size between 0.87 and 2.21. Conclusion The ATRS is a patient-reported instrument with high reliability, validity, and sensitivity for measuring outcome after treatment in patients with a total Achilles tendon rupture. Clinical Relevance The ATRS is a self-administered instrument with high clinical utility, and we suggest the score for measuring the outcome, related to symptoms and physical activity, after treatment in patients with a total Achilles tendon rupture.

Publisher

SAGE Publications

Subject

Physical Therapy, Sports Therapy and Rehabilitation,Orthopedics and Sports Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3