Biomechanical Analysis of Posterior Open-Wedge Osteotomy and Glenoid Concavity Reconstruction Using an Implant-Free, J-Shaped Iliac Crest Bone Graft

Author:

Ernstbrunner Lukas12,Borbas Paul3,Ker Andrew M.3,Imhoff Florian B.3,Bachmann Elias34,Snedeker Jess G.34,Wieser Karl3,Bouaicha Samy3

Affiliation:

1. Department of Orthopaedic Surgery, Royal Melbourne Hospital, Parkville, Victoria, Australia

2. Department of Biomedical Engineering, University of Melbourne, Parkville, Victoria, Australia

3. Department of Orthopaedics, Balgrist University Hospital, University of Zurich, Zurich, Switzerland

4. Laboratory for Orthopaedic Biomechanics, ETH Zurich, University of Zurich, Zurich, Switzerland

Abstract

Background: Posterior open-wedge osteotomy and glenoid reconstruction using a J-shaped iliac crest bone graft showed promising clinical results for the treatment of posterior instability with excessive glenoid retroversion and posteroinferior glenoid deficiency. Purpose: To evaluate the biomechanical performance of the posterior J-shaped graft to restore glenoid retroversion and posteroinferior deficiency in a cadaveric shoulder instability model. Study Design: Controlled laboratory study. Methods: A posterior glenoid open-wedge osteotomy was performed in 6 fresh-frozen shoulders, allowing the glenoid retroversion to be set at 0°, 10°, and 20°. At each of these 3 preset angles of glenoid retroversion, the following conditions were simulated: (1) intact joint, (2) posterior Bankart lesion, (3) 20% posteroinferior glenoid deficiency, and (4) posterior J-shaped graft (at 0° of retroversion). With the humerus in the Jerk position (60° of glenohumeral anteflexion, 60° of internal rotation), stability was evaluated by measuring posterior humeral head (HH) translation (in mm) and peak translational force (in N) to translate the HH over 25% of the glenoid width. Glenohumeral contact patterns were measured using pressure-sensitive sensors. Fixation of the posterior J-graft was analyzed by recording graft micromovements during 3000 cycles of 5-mm anteroposterior HH translations. Results: Reconstructing the glenoid with a posterior J-graft to 0° of retroversion significantly increased stability compared with a posterior Bankart lesion and posteroinferior glenoid deficiency in all 3 preset degrees of retroversion ( P < .05). There was no significant difference in joint stability comparing the posterior J-graft with an intact joint at 0° of retroversion. The posterior J-graft restored mean contact area and contact pressure comparable with that of the intact condition with 0° of retroversion (222 vs 223 mm2, P = .980; and 0.450 vs 0.550 MPa, P = .203). The mean total graft displacement after 3000 cycles of loading was 43 ± 84 µm, and the mean maximal mediolateral graft bending was 508 ± 488 µm. Conclusion: Biomechanical analysis of the posterior J-graft demonstrated reliable restoration of initial glenohumeral joint stability, normalization of contact patterns comparable with that of an intact shoulder joint with neutral retroversion, and secure initial graft fixation in the cadaveric model. Clinical Relevance: This study confirms that the posterior J-graft can restore stability and glenohumeral loading conditions comparable with those of an intact shoulder.

Publisher

SAGE Publications

Subject

Physical Therapy, Sports Therapy and Rehabilitation,Orthopedics and Sports Medicine

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3