Quantitative analysis of the measuring capabilities of the KT-1000 knee ligament arthrometer

Author:

Kowalk David L.1,Wojtys Edward M.1,Disher Jeff1,Loubert Peter1

Affiliation:

1. MedSport, University of Michigan Medical Center, Ann Arbor, Michigan

Abstract

The KT-1000 arthrometer was evaluated in vitro and in vivo to determine accuracy and quantify effects of potential error sources in clinical application. The KT- 1000 arthrometer in vitro accuracy was evaluated by making 30 measurements of 13 known displacements (range, +15 to -15 mm). The effect of applied force on malalignment measurements was evaluated in vitro by making repeated measurements with force applied 5°, 10°, and 15° from the vertical position. The effect of malpositioning the device along the joint line was eval uated in vivo by making repeated measurements 1 cm proximal and 1 cm distal to the joint line. The KT-1000 arthrometer was accurate in vitro (average error, 0.13 mm; SD, 0.12 mm). The range of measurements in creased when the angle of force application was in creased. Positioning the device 1 cm proximal to the joint line produced larger anterior translation measure ments in vivo than those at the joint line (5.8 versus 5.4 mm), while positioning it 1 cm distal produced smaller measurements (4.4 mm). The KT-1000 arthrometer's accuracy indicates great potential for clinical applica tion, but one must ensure that the displacing force is directed properly and the device is positioned accu rately over the joint line.

Publisher

SAGE Publications

Subject

Physical Therapy, Sports Therapy and Rehabilitation,Orthopedics and Sports Medicine

Reference17 articles.

1. Preoperative instrumented testing of anterior and posterior knee laxity

2. Blick SS, Daniel DM, Davis J., et al Kinematics of the quadriceps stabilized anterior cruciate disrupted knee Trans Orthop Res Soc 14 25, 1989

3. Fleming B., Beynnon B., Enckson A., et al An in vivo comparison of anterior joint laxity and strain in the anteromedial band of the anterior cruciate ligament Trans Orthop Res Soc 14 326, 1989

4. Forster IW, Warren-Smith CD, Tew M.: Is the KT-1000 knee ligament arthrometer reliable? J Bone Joint Surg 71B 843-847, 1989

5. An in vitro biomechanical evaluation of anterior-posterior motion of the knee. Tibial displacement, rotation, and torque.

Cited by 45 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3