Abstract

Background: Studies have demonstrated the acceptability of using a contralateral nonorthotopic lateral femoral condyle (LFC) graft for a circular medial femoral condyle (MFC) osteochondral defect up to 20 to 25 mm in diameter. Larger oblong defects can now be managed using either overlapping circle grafts or a single oblong-shaped osteochondral allograft (OCA). Purpose: To determine if an oblong contralateral nonorthotopic LFC OCA can attain an acceptable surface contour match compared with an oblong ipsilateral MFC OCA or an overlapping circle technique for large oblong defects of the MFC. Study Design: Controlled laboratory study. Methods: A total of 120 fresh-frozen human femoral condyles were matched by tibial width into 30 groups of 4 condyles (1 recipient MFC, 3 donor condyles). The recipient MFC was initially imaged using nano–computed tomography (nano-CT). A 17 × 36–mm oblong defect was created in the recipient MFC. Overall, 3 donor groups were formed: MFC oblong, LFC nonorthotopic oblong, LFC or MFC overlapping circles. After each transplant, the recipient condyle underwent nano-CT and was digitally reconstructed, which was superimposed on the initial nano-CT scan of the native recipient condyle. Dragonfly 3D software was used to determine the root mean square (RMS) of both the surface height deviation and the circumferential step-off height deviation between the native and donor cartilage surfaces for each graft. Results: RMS surface height deviations were as follows: 0.59 mm for MFC oblong grafts, 0.58 mm for LFC oblong grafts, and 0.78 mm for overlapping circle grafts. The MFC and LFC oblong grafts had significantly less surface height deviation than the overlapping circle grafts ( P = .004 and P = .002, respectively). RMS step-off height deviations were as follows: 0.68 mm for MFC oblong grafts, 0.70 mm for LFC oblong grafts, and 0.85 mm for overlapping circle grafts. The MFC and LFC oblong grafts had significantly less step-off height deviation than the overlapping circle grafts ( P < .001 and P = .002, respectively). The majority of this difference was on the medial segment of the overlapping circle grafts. Conclusion: Oblong ipsilateral MFC OCAs and oblong contralateral nonorthotopic LFC OCAs produced a significantly better surface contour match to the native MFC than overlapping circle grafts for oblong defects 17 × 36 mm in size. Clinical Relevance: Size-matched contralateral nonorthotopic LFC grafts are acceptable for MFC defects, which may allow for a quicker match, earlier patient care, and less wastage of valuable donor tissue.

Funder

JRF Ortho

Arthrex

Publisher

SAGE Publications

Subject

Physical Therapy, Sports Therapy and Rehabilitation,Orthopedics and Sports Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3