Return to Sports After Plate Fixation of Displaced Midshaft Clavicular Fractures in Athletes

Author:

Ranalletta Maximiliano1,Rossi Luciano A.1,Piuzzi Nicolás S.1,Bertona Agustin1,Bongiovanni Santiago L.1,Maignon Gaston1

Affiliation:

1. Institute of Orthopedics “Carlos E. Ottolenghi,” Italian Hospital of Buenos Aires, Buenos Aires, Argentina

Abstract

Background: Recent prospective randomized trials support primary plate fixation of displaced midshaft clavicle fractures. However, the safety and efficacy of this practice have not been well documented in athletes, nor has the time to return-to-sport. Purpose: To analyze the time to return-to-sport, functional outcomes, and complications in a group of athletes with displaced midshaft clavicle fractures treated using precontoured locking plates. Study Design: Case series; Level of evidence, 4. Methods: A total of 54 athletes with displaced midshaft clavicle fractures were treated with plate fixation between November 1, 2008, and December 31, 2012. The mean follow-up time was 22.4 months. Patients completed a questionnaire focused on the time to return-to-sport and treatment course. Functional outcomes were assessed with the Constant score and short version of the Disabilities of the Arm, Shoulder, and Hand (QuickDASH) questionnaire. Pain was evaluated with the visual analog scale (VAS). Radiographs were reviewed to identify radiographic union time, malunion, and nonunion. Results: Of the 54 patients, 53 returned to sports after open reduction and internal fixation of their fracture; 94% returned to the same level. The mean time to return-to-sport was 68 days (range, 5-180 days). Nine (16.6%) of the cases returned to sports before 6 weeks after surgery, 40 (74%) returned between 6 and 12 weeks, and 5 patients (9.2%) returned 12 weeks after surgery. The mean Constant score was 94.1 ± 5.2 (range, 78-100), and the mean QuickDASH score was 0.4 ± 4.7 (range, 0-7.1). The mean VAS pain score during follow-up was 0.29 ± 1.0 (range, 0-5). Three major complications occurred: 1 extrinsic compression of the subclavian vein, 1 nonunion, and 1 hardware loosening. Hardware removal was necessary in 5 patients (9.3%). Conclusion: Plate fixation of displaced clavicle fractures in athletes is a safe procedure resulting in excellent functional outcomes, with an early return to the same level of sports in the majority of patients.

Publisher

SAGE Publications

Subject

Physical Therapy, Sports Therapy and Rehabilitation,Orthopedics and Sports Medicine

Cited by 39 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3