Abstract

Background: Surgical management of cam femoroacetabular impingement (FAI) aims to preserve the native hip and restore joint function, although it is unclear how the capsulotomy, cam deformity, and capsular repair influence joint mechanics to balance functional mobility. Purpose: To examine the contributions of the capsule and cam deformity to hip joint mechanics. Using in vitro, cadaveric methods, we examined the individual effects of the surgical capsulotomy, cam resection, and capsular repair on passive range of motion and resistance of applied torque. Study Design: Descriptive laboratory study. Methods: Twelve cadaveric hips with cam deformities were skeletonized to the capsule and mounted onto a robotic testing platform. The robot positioned each intact hip in multiple testing positions: (1) extension, (2) neutral 0°, (3) flexion 30°, (4) flexion 90°, (5) flexion-adduction and internal rotation (FADIR), and (6) flexion-abduction and external rotation. Then the robot performed applicable internal and external rotations, recording the neutral path of motion until a 5-N·m of torque was reached in each rotational direction. Each hip then underwent a series of surgical stages (T-capsulotomy, cam resection, capsular repair) and was retested to reach 5 N·m of internal and external torque again after each stage. During the capsulotomy and cam resection stages, the initial intact hip’s recorded path of motion was replayed to measure changes in resisted torque. Results: Regarding changes in motion, external rotation increased substantially after capsulotomies, but internal rotation only further increased at flexion 90° (change +32%, P = .001, d = 0.58) and FADIR (change +33%, P < .001, d = 0.51) after cam resections. Capsular repair provided marginal restraint for internal rotation but restrained the external rotation compared with the capsulotomy stage. Regarding changes in torque, both internal and external torque resistance decreased after capsulotomy. Compared with the capsulotomy stage, cam resection further reduced internal torque resistance during flexion 90° (change −45%, P < .001, d = 0.98) and FADIR (change −37%, P = .003, d = 1.0), where the cam deformity accounted for 21% of the intact hip’s torsional resistance in flexion 90° and 27% in FADIR. Conclusion: Although the capsule played a predominant role in joint constraint, the cam deformity provided 21% to 27% of the intact hip’s resistance to torsional load in flexion and internal rotation. Resecting the cam deformity would remove this loading on the chondrolabral junction. Clinical Relevance: These findings are the first to quantify the contribution of the cam deformity to resisting hip joint torsional loads and thus quantify the reduced loading on the chondrolabral complex that can be achieved after cam resection.

Publisher

SAGE Publications

Subject

Physical Therapy, Sports Therapy and Rehabilitation,Orthopedics and Sports Medicine

Cited by 22 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3