Fasciotomy and Surgical Tenotomy for Recalcitrant Lateral Elbow Tendinopathy

Author:

Koh Joyce S.B.1,Mohan P.C.2,Howe T.S.1,Lee Brian P.3,Chia S.L.1,Yang Zixian4,Morrey Bernard F.5

Affiliation:

1. Department of Orthopaedic Surgery, Singapore General Hospital, Singapore

2. Department of Diagnostic Radiology, Singapore General Hospital, Singapore

3. Orthopaedic Associates, Mount Elizabeth Hospital, Singapore

4. Department of Occupational Therapy, Singapore General Hospital, Singapore

5. Department of Orthopaedic Surgery, Mayo Clinic and Mayo School of Medicine, Rochester, Minnesota

Abstract

Background:The optimal choice for intervention for recalcitrant lateral elbow tendinopathy remains unclear as various treatment modalities have documented comparable results in the literature.Purpose:To explore the safety, tolerability, and early efficacy of a new minimally invasive mode of treatment that delivers focused, calibrated ultrasonic energy, effectively microresecting the pathological tendon and removing only pathological tissue.Study Design:Case series; Level of evidence, 4.Methods:Seven male and 13 female patients aged 33 to 65 years averaging 12.5 months (range, 4-48) of failed nonoperative therapy underwent the ultrasonic microresection procedure in an outpatient clinic setting. The procedure involved a sterile, ultrasound-guided percutaneous microresection with a proprietary device (TX1) performed through a stab incision under local anesthesia. The duration of the procedure and complications of the device or procedure were assessed. Outcome parameters included patient satisfaction; visual analog scale (VAS) pain scores; Disabilities of the Arm, Shoulder and Hand (DASH) scores at 1, 3, 6, and 12 months; and ultrasound assessment at 3 and 6 months.Results:The median duration for the sterile confirmatory ultrasound examination (phase 1) was 88.5 seconds (range, 39-211; SD, ±47.6), the median duration of the procedure proper (phase 2) was 10.1 minutes (range, 4.1-19.4; SD, ±3.7), and the median energy time (duration the TX1 device was activated) was 32.5 seconds (range, 18-58; SD, ±11.0). No complications were encountered. A significant improvement in VAS score (from 5.5 to 3.3; P < .001) occurred by 1 week, and significant improvements in both DASH-Compulsory (from 21.7 to 11.3; P = .001) and DASH-Work (from 25.0 to 6.3; P = .012) scores occurred by 1 month. The VAS scores further improved at 3, 6, and 12 months (from 2.0 to 1.0 to 0.50; P = .003 and .023). The DASH-Compulsory score improved significantly from 3 to 6 months (from 8.6 to 4.6; P = .003), and both the DASH-Compulsory and DASH-Work scores were sustained by 12 months. Sonographically reduced tendon thickness (19 patients), resolved or reduced hypervascularity (17 patients), and reduced hypoechoic area (18 patients) occurred by 6 months. Nineteen of the 20 patients (95%) expressed satisfaction with the procedure, with 9 patients being very satisfied with their overall experience at 6 months after the procedure, 10 patients somewhat satisfied, and 1 patient neutral.Conclusion:Ultrasonic microresection of diseased tissue with the TX1 device provides a focally directed, safe, specific, minimally invasive, and well-tolerated treatment for recalcitrant lateral elbow tendinopathy in an office-based or ambulatory surgical setting with good evidence of some level of efficacy in 19 of 20 patients (95%) that is sustained for at least 1 year.

Publisher

SAGE Publications

Subject

Physical Therapy, Sports Therapy and Rehabilitation,Orthopedics and Sports Medicine

Cited by 78 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3