The strength of the central third patellar. tendon graft

Author:

Cooper Daniel E.1,Deng Xianghua H.1,Burstein Albert L.1,Warren Russell F.1

Affiliation:

1. Sports Medicine Service and Department of Biomechanics, The Hospital for Special Surgery, Cornell University Medical College, New York, New York

Abstract

Thirty-seven bone-patellar tendon-bone composite grafts from the knees of 21 human cadavers were tested to failure. Average donor age was 28 years. The composites were divided into 4 groups: 3 groups with 10 grafts (5 pairs) and 1 group with 7 grafts from 6 donors. In Group 1 we tested 10- versus 15-mm wide grafts that were used without twisting; Group II, 10- mm wide grafts without twisting versus 10-mm wide grafts that were twisted 90°; Group III, 10-mm wide grafts twisted 90° versus 10-mm wide grafts twisted 180°; and Group IV, 10- versus 7-mm wide grafts that were not twisted. The tests were performed using a newly described potting technique and clamp system and a servohydraulic testing machine with an elongation rate of 5 cm/sec. The results of this study suggest that the central third of the patellar tendon is stronger than previously re ported. The mean ultimate load of a 15-mm bone- patellar tendon-bone composite was 4389 N (±708); of the 10-mm wide composites, 2977 N (±516); and of the 7-mm composites, 2238 N (±316). Twisting the graft 90° increased the strength (P < 0.05). Further twisting to 180° had no significant effect compared with twisting 90°. This study supports the practice of using smaller (10 mm) bone-patellar tendon-bone grafts to avoid the potential complications of patellar fracture and graft impingement in the notch.

Publisher

SAGE Publications

Subject

Physical Therapy, Sports Therapy and Rehabilitation,Orthopedics and Sports Medicine

Reference27 articles.

1. Alm A., Eskström H., Strömberg B.: Tensile strength of the anterior cruciate ligament in the dog. Acta Chir Scand (Suppl) 445: 15-23, 1974

2. Barad S., Cabaud HE, Rodrigo JJ: Effects of storage at -80 degrees C as compared to 4 degrees C on the strength of rhesus monkey anterior cruciate ligaments. Trans Orthop Res Soc 7: 378, 1982

3. Butler DL, Hulse DA, Kay MD, et al: Biomechanics of cranial cruciate ligament reconstruction in the dog. II. Mechanical properties. Vet Surg 12: 113-118, 1983

4. Comparison of material properties in fascicle-bone units from human patellar tendon and knee ligaments

5. Butler DL, Noyes FR, Grood ES: Ligamentous restraints to anterior-posterior drawer in the human knee . A biomechanical study. J Bone Joint Surg 62A: 259-270, 1980

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3