Magnetic Resonance Imaging Assessment of Hamstring Graft Healing and Integration 1 and Minimum 2 Years after ACL Reconstruction

Author:

Putnis Sven E.12ORCID,Klasan Antonio3,Oshima Takeshi45,Grasso Samuel67,Neri Thomas89ORCID,Coolican Myles R.J.7,Fritsch Brett A.7,Parker David A.67

Affiliation:

1. Avon Orthopaedic Centre, Bristol, UK

2. University Hospitals Bristol & Weston NHS Foundation Trust, UK

3. Johannes Kepler University Linz, Linz, Austria

4. Department of Orthopaedic Surgery, Kanazawa University, Kanazawa, Japan

5. Asanogawa General Hospital, Kanazawa, Japan

6. University of Sydney, Sydney, Australia

7. Sydney Orthopaedic Research Institute, Sydney, Australia

8. Laboratory of Human Movement Science, University of Lyon – University Jean Monnet, Saint Etienne, France

9. Department of Orthopaedic Surgery, University Hospital of Saint-Etienne, France

Abstract

Background: An increase has been seen in the number of studies of anterior cruciate ligament reconstruction (ACLR) that use magnetic resonance imaging (MRI) as an outcome measure and proxy for healing and integration of the reconstruction graft. Despite this, the MRI appearance of a steady-state graft and how long it takes to achieve such an appearance have not yet been established. Purpose: To establish whether a hamstring tendon autograft for ACLR changes in appearance on MRI scans between 1 and 2 years and whether this change affects a patient’s ability to return to sports. Study Design: Case series; Level of evidence, 4. Methods: Patients with hamstring tendon autograft ACLR underwent MRI and clinical outcome measures at 1 year and at a final follow-up of at least 2 years. MRI graft signal was measured at multiple regions of interest using oblique reconstructions both parallel and perpendicular to the graft, with lower signal indicative of better healing and expressed as the signal intensity ratio (SIR). Changes in tunnel aperture areas were also measured. Clinical outcomes were side-to-side anterior laxity and patient-reported outcome measures (PROMs). Results: A total of 42 patients were included. At 1 year, the mean SIR for the graft was 2.7 ± 1.2. Graft SIR of the femoral aperture was significantly higher than that of the tibial aperture (3.4 ± 1.3 vs 2.6 ± 1.8, respectively; P = .022). Overall, no significant change was seen on MRI scans after 2 years; a proximal graft SIR of 1.9 provided a sensitivity of 96% to remain unchanged. However, in the 6 patients with the highest proximal graft SIR (>4) at 1 year, a significant reduction in signal was seen at final follow-up ( P = .026), alongside an improvement in sporting level. A significant reduction in aperture area was also seen between 1 and 2 years (tibial, –6.3 mm2, P < .001; femoral, –13.3 mm2, P < .001), which was more marked in the group with proximal graft SIR >4 at 1 year and correlated with a reduction in graft signal. The patients had a high sporting level; the median Tegner activity score was 6 (range, 5-10), and a third of patients scored either 9 or 10. Overall, PROMs and knee laxity were not associated with MRI appearance. Conclusion: In the majority of patients, graft SIR on MRI did not change significantly after 1 year, and a proximal graft SIR <2 was a sensitive indicator for a stable graft signal, implying healing. Monitoring is proposed for patients who have a high signal at 1 year (proximal graft SIR >4), because a significant reduction in signal was seen in the second year, indicative of ongoing healing, alongside an improvement in sporting level. A reduction in tunnel aperture area correlated with a reduction in graft SIR, suggesting this could also be a useful measure of graft integration.

Funder

Arthrex

Publisher

SAGE Publications

Subject

Physical Therapy, Sports Therapy and Rehabilitation,Orthopedics and Sports Medicine

Cited by 4 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3