Isokinetic Evaluation of Internal/External Tibial Rotation Strength after the Use of Hamstring Tendons for Anterior Cruciate Ligament Reconstruction

Author:

Armour Tanya1,Forwell Lorie1,Litchfield Robert1,Kirkley Alexandra,Amendola Ned2,Fowler Peter J.1

Affiliation:

1. Fowler Kennedy Sport Medicine Clinic, London, Ontario, Canada

2. University of Iowa, Iowa City, Iowa

Abstract

Background Evaluation of the knee after an anterior cruciate ligament reconstruction with the use of the semitendinosus and gracilis (hamstring) autografts has primarily focused on flexion and extension strength. The semitendinosus and gracilis muscles contribute to internal tibial rotation, and it has been suggested that harvest of these tendons for the purpose of an anterior cruciate ligament reconstruction contributes to internal tibial rotation weakness. Hypothesis Internal tibial rotation strength may be affected by the semitendinosus and gracilis harvest after anterior cruciate ligament reconstruction. Study Design Prospective evaluation of internal and external tibial rotation strength. Methods Inclusion criteria for subjects (N = 30): unilateral anterior cruciate ligament reconstruction at least 2 years previously, a stable anterior cruciate ligament (<5-mm side-to-side difference) at time of testing confirmed by surgeon and KT-1000 arthrometer, no history of knee problems after initial knee reconstruction, a normal contralateral knee, and the ability to comply with the testing protocol. In an attempt to minimize unwanted subtalar joint motion, subjects were immobilized using an ankle brace and tested at angular velocities of 60°/s, 120°/s, and 180°/s at a knee flexion angle of 90°. Results The mean peak torque measurements for internal rotation strength of the operative limb (60°/s, 17.4 ± 4.5 ft-lb; 120°/s, 13.9 ± 3.3 ft-lb; 180°/s, 11.6 ± 3.0 ft-lb) were statistically different compared to the nonoperated limb (60°/s, 20.5 ± 4.7 ft-lb; 120°/s, 15.9 ± 3.8 ft-lb; 180°/s, 13.4 ± 3.8 ft-lb) at 60°/s (P = .012), 120°/s (P = .036), and 180°/s (P = .045). The nonoperative limb demonstrated greater strength at all speeds. The mean torque measurements for external rotation were statistically similar when compared to the nonoperated limb at all angular velocities. Conclusions We have shown through our study that patients who undergo surgical intervention to repair a torn anterior cruciate ligament with the use of autogenous hamstring tendons demonstrate with weaker internal tibial rotation postoperatively at 2 years when compared to the contralateral limb.

Publisher

SAGE Publications

Subject

Physical Therapy, Sports Therapy and Rehabilitation,Orthopedics and Sports Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3