Effect of Tunnel-Graft Length on the Biomechanics of Anterior Cruciate Ligament-Reconstructed Knees

Author:

Zantop Thore12,Ferretti Mario1,Bell Kevin M.1,Brucker Peter U.1,Gilbertson Lars1,Fu Freddie H.1

Affiliation:

1. Department of Orthopaedic Surgery, University of Pittsburgh Medical Center, Pittsburgh, Pennsylvania

2. Department of Trauma-, Hand-, and Reconstructive Surgery, Westfälische Wilhelms-University Münster, Münster, Germany

Abstract

Background In anterior cruciate ligament (ACL) reconstruction using hamstring grafts, the graft can be looped, resulting in an increased graft diameter but reducing graft length within the tunnels. Hypothesis After 6 and 12 weeks, structural properties and knee kinematics after soft tissue ACL reconstruction with 15 mm within the femoral tunnel will be significantly inferior when compared with the properties of ACL reconstruction with 25 mm in the tunnel. Study Design Controlled laboratory study. Methods In an intra-articular goat model, 36 ACL reconstructions using an Achilles tendon split graft were performed with 15-mm (18 knees) and 25-mm (18 knees) graft length in the femoral tunnel. Animals were sacrificed 6 weeks and 12 weeks after surgery and knee kinematics was tested. In situ forces as well as the structural properties were determined and compared with those in an intact control group. Histologic analyses were performed in 2 animals in each group 6 and 12 weeks postoperatively. Statistical analysis was performed using a 2-factor analysis of variance test. Results Anterior cruciate ligament reconstructions with 15 mm resulted in significantly less anterior tibial translation after 6 weeks ( P < .05) but not after 12 weeks. Kinematics after 12 weeks and in situ forces of the replacement grafts at both time points showed no statistically significant differences. Stiffness, ultimate failure load, and ultimate stress revealed no statistically significant differences between the 15-mm group and the 25-mm group. Conclusion The results suggest that there is no negative correlation between short graft length (15 mm) in the femoral tunnel and the resulting knee kinematics and structural properties. Clinical Relevance Various clinical scenarios exist in which the length of available graft that could be pulled into the bone tunnel (femoral or tibial) could be in question. To address this concern, this study showed that reducing the tendon graft length in the femoral bone tunnel from 25 mm to 15 mm did not have adverse affects in a goat model.

Publisher

SAGE Publications

Subject

Physical Therapy, Sports Therapy and Rehabilitation,Orthopedics and Sports Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3