Biomechanical Comparison of Fiber Tape Device Versus Transarticular Screws for Ligamentous Lisfranc Injury in a Cadaveric Model

Author:

Koroneos Zachary A.1,Manto Kristen M.1,Martinazzi Brandon J.1,Stauch Chris1,Bifano Shawn M.1,Kunselman Allen R.2,Lewis Gregory S.1,Aynardi Michael1

Affiliation:

1. Department for Orthopaedics and Rehabilitation, The Pennsylvania State University, Hershey, Pennsylvania, USA

2. Division of Biostatistics and Bioinformatics, Department of Public Health Sciences, The Pennsylvania State University, Hershey, Pennsylvania, USA

Abstract

Background: The preferred method of fixation and surgical treatment for ligamentous Lisfranc injuries is controversial. Transarticular screws, bridge plating, fusion, and flexible fixation have been described, yet none have demonstrated superiority. Furthermore, screw fixation and plating often require secondary surgery to remove implants, leading surgeons to seek alternative fixation methods. Purpose: To compare transarticular screws and a fiber tape construct under a spectrum of biomechanical loads by evaluating the diastasis at 3 joints in the Lisfranc complex. Study Design: Controlled laboratory study. Methods: Eight matched pairs of fresh, previously frozen lower extremity cadaveric specimens were fixed with either 2 cannulated transarticular crossed screws or a fiber tape construct with a supplemental intercuneiform limb. The diastasis between bones was measured at 3 midfoot joints in the Lisfranc complex: the Lisfranc articulation, the second tarsometatarsal joint, and the intercuneiform joint. Measurements were obtained for the preinjured, injured, and fixation conditions under static loading at 50% donor body weight. Specimens then underwent cyclic loading performed at 1 Hz and 100 cycles, based on 100-N stepwise increases in ground-reaction force from 100 to 2000 N, to simulate postoperative loading from the partial weightbearing stage to high-energy activities. Failure of fixation was defined as diastasis ≥2 mm at the Lisfranc articulation (second metatarsal–medial cuneiform joint). Results: There were no significant differences in diastasis detected at the Lisfranc articulation or the intercuneiform joint throughout all loading cycles between groups. All specimens endured loading up to 50% body weight + 1400 N. Up to and including this stage, there were 2 failures in the cannulated transarticular crossed-screw group and none in the fiber tape group. Conclusion: The fiber tape construct with a supplemental intercuneiform limb, which does not require later removal, may provide comparable biomechanical stability to cannulated transarticular crossed screws, even at higher loads. Clinical Relevance: Ligamentous Lisfranc injuries are common among athletes. Therefore, biomechanical evaluations are necessary to determine stable constructs that can limit the time to return to play. This study compares the biomechanical stability of 2 methods of fixation for ligamentous injury through a wide spectrum of loading, including those experienced by athletes.

Funder

Arthrex

Publisher

SAGE Publications

Subject

Physical Therapy, Sports Therapy and Rehabilitation,Orthopedics and Sports Medicine

Cited by 7 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3