Validation of an MRI Protocol for Routine Quantitative Assessment of Tunnel Position in Anterior Cruciate Ligament Reconstruction

Author:

Grasso Samuel12,Linklater James3,Li Qing2,Parker David A.14

Affiliation:

1. Sydney Orthopaedic Research Institute, Chatswood, Australia

2. School of Aerospace, Mechanical and Mechatronic Engineering, University of Sydney, Sydney, Australia

3. Castlereagh Imaging, St Leonards, Australia

4. North Shore Knee Clinic, Sydney, Australia

Abstract

Background: No standardized methodology and objective criteria currently exist to accurately and objectively assess tunnel placement and consequent graft orientation in anterior cruciate ligament (ACL) reconstruction (ACLR) through a single imaging modality. Advances in magnetic resonance imaging (MRI) technology have enabled the use of volumetric high spatial and contrast resolution proton density–weighted sequencing, which allows precise delineation of graft orientation, tunnel position, and quantitative assessment of tunnel position relationship to adjacent reproducible anatomic landmarks. Purpose: To establish an MRI protocol that would provide an accurate alternative to 3-dimensional computed tomography (3D-CT) for standardized assessment of bone tunnel placement in ACLR, as a component of assessing ACLR outcomes and to assist in presurgical planning for revision ACLR. Study Design: Cohort study (diagnosis); Level of evidence, 2. Methods: Twenty-four participants diagnosed with a failed ACLR underwent MRI and 3D-CT per the imaging protocols of the Sydney Orthopaedic Research Institute, in which the acquired data were converted to 3D models. The bone tunnels of the previous ACLR were then intraoperatively digitized at the tunnel aperture and along the length of the tunnel (barrel) and used as the reference standard to evaluate the accuracy of high-resolution MRI and 3D-CT. Differences in geometry between the image-based model and the reference point cloud were calculated through point-to-point comparison. Results: At the tunnel apertures, no significant differences were detected between the MRI and 3D-CT models versus the reference models for the femur ( P = .9472) and tibia ( P = .5779). Mean ± SD tunnel barrel deviations between MRI and 3D-CT were 0.48 ± 0.28 mm (femur) and 0.46 ± 0.27 mm (tibia). No significant differences were detected between the MRI and 3D-CT models versus the reference models for the femoral ( P = .5730) and tibial ( P = .3002) tunnel barrels. Conclusion: This study demonstrated that, in addition to being the optimum modality for assessment of soft tissue injury of the knee, a high-resolution 3D turbo spin echo proton density sequence can provide an accurate assessment of tunnel placement, without the use of ionizing radiation. Therefore, this protocol provides the foundation for an objective standardized platform to quantitatively evaluate the location of ACL bone tunnels and graft orientation for routine postoperative assessment, presurgical planning, and evaluation of clinical outcomes.

Publisher

SAGE Publications

Subject

Physical Therapy, Sports Therapy and Rehabilitation,Orthopedics and Sports Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3