Biomechanical Comparison of Onlay Distal Biceps Tendon Repair: All-Suture Anchors Versus Titanium Suture Anchors

Author:

Otto Alexander123,Mehl Julian2,Obopilwe Elifho1,Cote Mark1,Lacheta Lucca2,Scheiderer Bastian2,Imhoff Andreas B.2,Mazzocca Augustus D.1,Siebenlist Sebastian2

Affiliation:

1. Department of Orthopaedic Surgery, UConn Musculoskeletal Institute, University of Connecticut, Farmington, Connecticut, USA

2. Department of Orthopaedic Sports Medicine, Klinikum rechts der Isar, Technical University of Munich, Munich, Germany

3. Department of Trauma, Orthopaedic, Plastic and Hand Surgery, University Hospital of Augsburg, Augsburg, Germany

Abstract

Background: A rupture of the distal biceps tendon is the most common tendon rupture of the elbow and has received increased attention in the past few years. Newly developed all-suture anchors have the potential to minimize surgical trauma and the risk of adverse events because of the use of flexible drills and smaller drill diameters. Purpose/Hypothesis: The purpose was to biomechanically compare all-suture anchors and titanium suture anchors for distal biceps tendon repair in cadaveric specimens. The hypothesis was that all-suture anchors would show no differences in load to failure or displacement under cyclic loading compared with titanium suture anchors. Study Design: Controlled laboratory study. Methods: Sixteen unpaired, fresh-frozen human cadaveric elbows were randomized to 2 groups, which underwent onlay distal biceps tendon repair with 2 anchors. Bone mineral density at the radial tuberosity was evaluated in each specimen. In the first group, distal biceps tendon repair was performed using all-suture anchors. In the second group, titanium suture anchors were applied. After cyclic loading for 3000 cycles, the repair constructs were loaded to failure. The peak load to failure as well as repair construct stiffness and mode of failure were determined. Results: The mean (±SD) peak load was 293.53 ± 122.15 N for all-suture anchors and 280.02 ± 69.34 N for titanium suture anchors ( P = .834); mean stiffness was 19.78 ± 2.95 N/mm and 19.30 ± 4.98 N/mm, respectively ( P = .834). The mode of failure was anchor pullout for all specimens during load to failure. At the proximal position, all-suture anchors showed a displacement of 1.53 ± 0.80 mm, and titanium suture anchors showed a displacement of 0.81 ± 0.50 mm ( P = .021) under cyclic loading. At the distal position, a displacement of 1.86 ± 1.04 mm for all-suture anchors and 1.53 ± 1.15 mm for titanium suture anchors was measured ( P = .345). A positive correlation between bone mineral density and load to failure was observed ( r = 0.605; P = .013). Conclusion: All-suture anchors were biomechanically equivalent at time zero to titanium suture anchors for onlay distal biceps tendon repair. While the proximally placed all-suture anchors demonstrated greater displacement than titanium suture anchors, the comparable displacement at the distal position as well as the similar load and mechanism of failure make this difference unlikely to be clinically significant. Clinical Relevance: All-suture anchors performed similarly to titanium suture anchors for onlay distal biceps tendon repair at time zero and represent a reasonable alternative.

Publisher

SAGE Publications

Subject

Physical Therapy, Sports Therapy and Rehabilitation,Orthopedics and Sports Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3