A Multicenter Study of Radiographic Measures Predicting Failure of Arthroscopy in Borderline Hip Dysplasia: Beware of the Tönnis Angle

Author:

McQuivey Kade S.1,Secretov Erwin2,Domb Benjamin G.3,Levy Bruce A.4,Krych Aaron J.4,Neville Matthew1,Hartigan David E.5

Affiliation:

1. Department of Orthopedics, Mayo Clinic Arizona, Phoenix, Arizona, USA

2. Department of Orthopedics, University of Illinois, Chicago, Illinois, USA

3. Department of Orthopedics, American Hip Institute, Des Plaines, Illinois, USA

4. Department of Orthopedics, Mayo Clinic, Rochester, Minnesota, USA

5. Department of Orthopedic Surgery, Twin Cities Orthopedics, Minneapolis, Minnesota, USA

Abstract

Background:Hip arthroscopy has been previously demonstrated to be an effective treatment for adult mild hip dysplasia. There are many radiographic parameters used to classify hip dysplasia, but to date few studies have demonstrated which parameters are of most importance for predicting surgical outcomes.Purpose:To identify preoperative radiographic parameters that are associated with poor outcomes in the arthroscopic treatment of adult mild hip dysplasia.Study Design:Case-control study; Level of evidence, 3.Methods:Radiographic analysis was performed in patients with mild hip dysplasia who underwent arthroscopic surgery between 2009 and 2015. Preoperative radiographic measurements included lateral center edge angle, Tönnis angle, neck shaft angle, anterior center edge angle, alpha angle, femoral head extrusion index, and acetabular depth-to-width ratio. Failure was defined as failure to achieve the minimal clinically important difference (MCID) utilizing the modified Harris Hip Score or as the need for secondary operation. The equal variance t test was used to analyze radiographic parameters. Statistical significance was determined using a P value of .05.Results:A total of 373 hips underwent analysis with an average follow-up of 41 months (range, 24-102 months). Of these, 46 hips (12%) required secondary operation, and 95 (25%) failed to meet the MCID. The overall failure rate was 32.4%. There was no single measurement or combination thereof associated with failure to reach the MCID. Higher preoperative Tönnis angles were associated with secondary operation, with a mean of 6.7° (95% CI, 5.3°-8.1°) in the secondary operation group versus 4.8° (95% CI, 4.4°-5.3°) in the nonsecondary operation group ( P = .006). The odds ratio was 1.12 (95% CI, 1.0-1.2; P = .05) per degree increase in Tönnis angle for secondary operation. In patients with a Tönnis angle >10°, 84% required secondary operation.Conclusion:Higher Tönnis angles portend a higher risk for revision surgery. The probability of secondary operation was increased by a magnitude of 1.12 with each degree increase in the Tönnis angle. In patients with a Tönnis angle >10°, 84% required a secondary operation.

Publisher

SAGE Publications

Subject

Physical Therapy, Sports Therapy and Rehabilitation,Orthopedics and Sports Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3