Distal Biceps Tendon Repair

Author:

Idler Cary S.1,Montgomery William H.2,Lindsey Derek P.3,Badua Peter A.2,Wynne Garnet F.2,Yerby Scott A.134

Affiliation:

1. San Francisco Orthopaedic Residency Program, San Francisco, California

2. St Mary's Medical Center, San Francisco, California

3. VA Rehabilitation R&D Center, Palo Alto, California

4. St Francis Medical Technologies, Alameda, California

Abstract

Background A variety of techniques have been described for distal biceps tendon reattachment—bone tunnel with transosseous sutures, suture anchors, and interference screw techniques. Hypothesis There will be no significant difference between the mean failure strength, maximum strength, and stiffness of the intact specimen and repair techniques tested: bone tunnel with transosseous sutures and interference screw. Study Design Controlled laboratory study. Methods Nine matched pairs of fresh-frozen human cadaveric elbows were prepared. The intact tendon was pulled from the radial tuberosity; the right and left elbows were randomized to bone tunnels with transosseous sutures or interference screw repair techniques. The repaired specimens were pulled using the same regimen for the intact tendon. Failure strength, maximum strength, and stiffness were measured and compared. Results The mean failure strength, maximum strength, and stiffness of intact tendons were 204.3 ± 76.9 N, 221.7 ± 65.9 N, and 30.1 ± 12.4 N/mm, respectively; for the interference screw specimens, 178.0 ± 54.5 N, 192.1 ± 53.1 N, and 30.4 ± 9.5 N/mm, respectively; and for the bone tunnel specimens, 124.9 ± 22.8 N, 206.6 ± 49.8 N, and 15.9 ± 5.6 N/mm, respectively. There were no significant differences between measures in the intact and interference screw specimens. Mean failure strength and stiffness of the bone tunnel specimens were significantly lower than those of the intact and interference screw specimens; there was no significant difference between the maximum strengths of the treatments. Interference screw failure occurred abruptly with little plastic deformation in nearly all specimens with the tendon and screw pulling out as a unit, often involving fracture of the radial wall. Two of the bone tunnels failed at the bony bridge; the remainder lost bone-tendon contact as the distal tendon was shredded by the suture. Conclusion The results suggest interference screw fixation repair is nearly as strong and stiff as the intact tendon and stronger than the bone tunnel repair technique. Clinical Relevance The interference screw provides better stiffness and failure strength compared with the bone tunnel technique for distal biceps tendon repair. Given the superior mechanical properties, the interference screw technique is recommended as the treatment of choice for biceps tendon rupture repair.

Publisher

SAGE Publications

Subject

Physical Therapy, Sports Therapy and Rehabilitation,Orthopedics and Sports Medicine

Cited by 111 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3