Biomechanical Comparison of the Docking Technique with and without Humeral Bioabsorbable Interference Screw Fixation

Author:

Hurbanek Jason G.1,Anderson Kyle2,Crabtree Stephanie3,Joshua Karnes G.3

Affiliation:

1. Henry Ford Hospital, Detroit, Michigan

2. William Beaumont Hospital, Royal Oak, Michigan

3. Arthrex, Inc, Naples, Florida

Abstract

Background Surgical reconstruction of the ulnar collateral ligament has evolved since Frank Jobe's original description. The “docking technique” is a popular modification that allows for securing the graft within a single humeral tunnel. More recently, interference screw fixation has been introduced as a means of improving the ultimate strength, stiffness, and kinematics of these constructs. Purpose This study was conducted to compare the biomechanical performance of the docking technique with and without interference screw fixation in the humerus. Study Design Controlled laboratory study. Methods Nine matched pairs of human cadaveric elbows (age 49.9 ± 8.0 years) were reconstructed with a tendon graft using the docking technique (group 1) or the docking technique with the addition of a 4.75-mm bioabsorbable humeral interference screw (group 2). Before the reconstruction, joint laxity was measured on each specimen with the ulnar collateral ligament intact and then after transection of the ligament. Laxity measurements were repeated after the reconstruction. Failure testing was then performed at 70° of elbow flexion. The specimens were preloaded with a 1-N·m moment and then loaded to failure at a displacement rate of 14 mm/s to approximate 50% strain per second. Results Within group 1, the elbow laxity of the reconstructed state was significantly greater than the intact state at all tested flexion angles (P <. 021). Within group 2, no statistically significant difference existed in elbow laxity between the intact state and the reconstructed state. When comparing laxities between groups, group 1 tended to be more lax at all tested flexion angles but was only significantly greater at 105° of flexion. The most common mode of failure for both groups involved the sutures pulling out of the tendon. No significant difference was found for ultimate moment of failure between the 2 groups. However, the moment associated with 3 mm of gap formation for group 2 (12.8 ± 4.2 N·m) was statistically greater than that of group 1 (7.5 ± 1.2 N·m) (P =. 001). The stiffness of group 2 (14.7 ± 6.4 N/mm) was significantly greater than group 1 (9.9 ± 3.1 N/mm) (P =. 044). Conclusion The biomechanical performance of the docking technique with and without a humeral interference screw is similar. Clinical Relevance The stiffness of the construct, along with the difference in moment that allows a 3-mm gap formation, suggests that the addition of a humeral interference screw is potentially beneficial. Further research in a healing model will help clarify this benefit.

Publisher

SAGE Publications

Subject

Physical Therapy, Sports Therapy and Rehabilitation,Orthopedics and Sports Medicine

Cited by 19 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3