Affiliation:
1. Department of Orthopaedics, University of Florida, Gainesville, Florida
Abstract
A prospective clinical study of the results of prosthetic ligament replacement of the ACL with the Gore-Tex polytetrafluoroethylene prosthesis was undertaken. Thirty-three (80%) of 41 patients were available at a minimum 36 month followup (mean, 48 months; range, 36 to 62). Kaplan-Meier survival analysis revealed an 82% probability of survival of the polytetrafluoroethyl ene ligament at the 48 month followup. When compared to the same data at a minimum 24 month followup, the results appeared to have deterioriated somewhat over time. Three possible "predictors" of failure at later fol lowup were identified: preoperative subjective symp toms of swelling, subjective symptoms of giving way at 2 years, and an increased anterior drawer sign at 2 years.
Subject
Physical Therapy, Sports Therapy and Rehabilitation,Orthopedics and Sports Medicine
Cited by
91 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献