Biologic fixation of ligament prostheses and augmentations

Author:

Arnoczky Steven P.1,Torzilli Peter A.2,Warren Russell F.1,Allen Answorth A.1

Affiliation:

1. Laboratories of Comparative Orthopaedics and Sports Medicine Research, New York Hospital, Cornell University Medical College, New York, New York

2. Department of Biomechanics, The Hospital for Special Surgery, New York, New York, New York Hospital, Cornell University Medical College, New York, New York

Abstract

The biologic fixation (bone ingrowth) of three prosthetic ligament devices (bovine xenograft Xenotech Labora tories, Inc., Irvine, CA; Gore-Tex, W. L. Gore and As sociates, Flagstaff, AZ; and knitted dacron, Stryker, Kalamazoo, MI) and one ligament augmentation device (LAD, braided polypropylene, 3M, St. Paul, MN) were evaluated in vivo. The devices were placed unstressed, in an extraarticular location in the cortical-cancellous bone of the proximal femur and humerus of dogs. Six months following implantation tissue ingrowth was eval uated using high resolution radiography, routine histol ogy, scanning electron microscopy, and biomechanical tensile tests to measure the ultimate (maximum) pull- out strength of the devices. The knitted dacron and Gore-Tex prosthesis showed marked ingrowth of trabecular bone into the interstices of the device with evidence of bone growth around individual fibers of the prosthesis. The bovine xenograft demonstrated bone immediately adjacent to the mate rial with evidence of spicular ingrowth of bone into the natural clefts of the prosthesis. The LAD showed no evidence of bone ingrowth and demonstrated a fibrous tissue interface between the prosthesis and surround ing trabecular bone. Six months following implantation the pull-out strengths of the devices were as follows: knitted dac ron, 445.7 ± 151.ON; Gore-Tex, 438.1 ± 131.94N; bovine xenograft, 332.8 ± 64.2N; and LAD, 78.4 ± 47.9N. Statistical analysis revealed no significant differ ence between the pull-out strengths of the knitted dacron, Gore-Tex, and bovine xenograft. While the pull- out strength of the LAD was significantly lower (P < 0.01) than the other devices it should be noted that this device was designed as a temporary augmentation for biological grafts and as such permanent biological fix ation through bone ingrowth is neither required nor desired. The Gore-Tex, LAD, and bovine xenograft devices all failed by pulling out of the bone tunnel, while all the dacron grafts failed by separation of the dacron outer sleeve of the prosthesis from its inner dacron reinforcement. This rupture occurred at the entrance of the graft into the bone tunnel.

Publisher

SAGE Publications

Subject

Physical Therapy, Sports Therapy and Rehabilitation,Orthopedics and Sports Medicine

Cited by 63 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3