Abstract

Background: Compared with a patellar tendon autograft (PT), a hamstring tendon autograft (HT) has an increased risk of revision after anterior cruciate ligament reconstruction (ACLR). There are no studies analyzing whether this can be explained by inferior fixation devices used in HT reconstruction or whether the revision risk of ACLR with an HT or a PT is influenced by the graft fixation. Purpose: To compare the risk of revision and the revision rates between the most commonly used combinations of fixation for HTs with PTs. Study Design: Cohort study; Level of evidence, 2. Methods: This study included all patients registered in the Norwegian Knee Ligament Registry from 2004 through 2013 who underwent primary PT or HT ACLR with no concomitant ligament injury and known graft fixation. The 2-year revision rates were calculated using the Kaplan-Meier analysis. Hazard ratios (HRs) for revision at 2 years were calculated using multivariate Cox regression models. Results: A total of 14,034 patients with primary ACLR were identified: 3806 patients with PTs and 10,228 patients with HTs; the mean follow-up time was 4.5 years. In the HT group, 5 different combinations of fixation in the femur/tibia were used in more than 500 patients: Endobutton/RCI screw (n = 2339), EZLoc/WasherLoc (n = 1352), Endobutton/Biosure HA (n = 1209), Endobutton/Intrafix (n = 687), and TransFix II/metal interference screw (MIS) (n = 620). The crude 2-year revision rate for patients with PTs was 0.7% (95% CI, 0.4%-1.0%), and for patients with HTs, it ranged between the groups from 1.5% (95% CI, 0.5%-2.4%) for TransFix II/MIS to 5.5% (95% CI, 4.0%-7.0%) for Endobutton/Biosure HA. When adjusted for detected confounding factors and compared with patients with PTs, the HR for revision at 2 years was increased for all HT combinations used in more than 500 patients, and the combinations Endobutton/Biosure HA and Endobutton/Intrafix had the highest HRs of 7.3 (95% CI, 4.4-12.1) and 5.5 (95% CI, 3.1-9.9), respectively. Conclusion: The choice of fixation after ACLR with an HT has a significant effect on a patient’s risk of revision. In this study population, none of the examined combinations of HT fixation had a revision rate as low as that for a PT.

Publisher

SAGE Publications

Subject

Physical Therapy, Sports Therapy and Rehabilitation,Orthopedics and Sports Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3