Quantification Analysis of the Intraoperative Bacterial Contamination Rate and Level in Osteochondral Autografts

Author:

Alomar Abdulaziz Z.1,Somily Ali Mohammed2,Alraiyes Thamer M.3,Bin Nasser Ahmad S.1,Aljassir Fawzi F.1

Affiliation:

1. Orthopaedic Department, King Saud University Medical City, College of Medicine, King Saud University, Riyadh, Saudi Arabia

2. Department of Pathology and Laboratory Medicine/Microbiology Unit, King Saud University Medical City, College of Medicine, King Saud University. Riyadh, Saudi Arabia

3. Orthopaedic Department, McGill University, Montreal, Quebec, Canada

Abstract

Background: Inadvertent contamination of osteochondral (OC) autografts during harvesting and preparation can lead to significant complications and can cause the operating team to weigh the infection risk after reimplantation against discarding the OC fragment. The most commonly reported contamination mechanism is the accidental dropping of an OC fragment; however, associated contamination levels remain unclear. The rate and level of contamination during standard harvesting and preparation are also unknown. Purpose: To quantitatively evaluate the rate and level of bacterial contamination of OC autografts during harvesting and preparation compared with those of accidently dropped autografts. Study Design: Controlled laboratory study. Methods: Under sterile conditions, 138 fresh OC specimens were harvested and retrieved from 23 primary total knee arthroplasties (TKAs). Six OC fragments were retrieved from each TKA: 3 were used as controls, and 3 were dropped onto the operating room floor. Each specimen was incubated to allow for aerobic and anaerobic growth, and the number of colony-forming units (CFUs) per gram was calculated. Results: Contamination rates (positive cultures) for the control and dropped groups were 29% (n = 20/69) and 42% (n = 29/69), respectively. The difference in the contamination rate between groups was not statistically significant ( P = .109). The most common organisms identified were Staphylococcus aureus (40%) in the control group and Staphylococcus epidermidis (24.1%) and Bacillus species (20.7%) in the dropped group. The contamination level (CFUs/g) for both groups was low. The median (range) CFUs/g among the contaminated specimens in the dropped and control groups were 27 (1-120) and 3 (1-15), respectively ( P < .0001). Conclusion: A relatively high rate of OC autograft contamination can be expected during harvesting and preparation (29%) or after accidentally dropping a specimen (42%). Although the types of organisms isolated differed between specimens contaminated during harvesting and preparation and dropped specimens, the quantification of the autograft contamination level revealed a very low CFUs/g in both cases. Clinical Relevance: The intraoperative autograft contamination level is very low. Hence, in cases of grafts with a known contamination incident, saving and reimplanting them after proper decontamination is recommended over discarding them or using an allograft.

Publisher

SAGE Publications

Subject

Physical Therapy, Sports Therapy and Rehabilitation,Orthopedics and Sports Medicine

Cited by 6 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3