Biomechanical Role of Capsular Continuity in Superior Capsule Reconstruction for Irreparable Tears of the Supraspinatus Tendon

Author:

Mihata Teruhisa12,McGarry Michelle H.1,Kahn Timothy1,Goldberg Iliya1,Neo Masashi2,Lee Thay Q.1

Affiliation:

1. Orthopaedic Biomechanics Laboratory, VA Long Beach Healthcare System and University of California, Irvine, Long Beach, California, USA

2. Department of Orthopedic Surgery, Osaka Medical College, Takatsuki, Japan

Abstract

Background: Patients with irreparable rotator cuff tears have a defect of the superior capsule, which creates discontinuity of the shoulder capsule in the transverse direction (anterior-posterior direction). This effect is one of the causes underlying shoulder instability after rotator cuff tears. Purpose/Hypothesis: The purpose of this study was to assess the effects of anterior and posterior continuity on shoulder biomechanics after superior capsule reconstruction (SCR). The hypothesis was that capsular continuity in the transverse direction would improve glenohumeral stability after SCR. Study Design: Controlled laboratory study. Methods: Seven fresh-frozen cadaveric shoulders were tested by using a custom shoulder testing system. Subacromial peak contact pressure, glenohumeral superior translation, glenohumeral compression force, and glenohumeral range of motion (ROM) were compared among 5 conditions: (1) intact shoulder, (2) simulated irreparable supraspinatus tendon tear, (3) SCR without side-to-side suturing, (4) SCR with posterior side-to-side suturing, and (5) SCR with both anterior and posterior side-to-side suturing. Results: The creation of an irreparable supraspinatus tear significantly increased glenohumeral superior translation (0° of abduction: 254% of intact [ P = .04]; 30° of abduction: 200% of intact [ P = .04]) and subacromial peak contact pressure (0° of abduction: 302% of intact [ P = .0001]; 30° of abduction: 239% of intact [ P = .0006]), decreased glenohumeral compression force (0° of abduction: 85% of intact [ P = .004]; 30° of abduction: 87% of intact [ P = .0002]; 60° of abduction: 88% of intact [ P = .0001]), and increased total ROM (0° of abduction: 16° increase [ P = .008]). SCR without side-to-side suturing significantly decreased subacromial peak contact pressure (0° of abduction: 79% of intact [ P = .0001]; 30° of abduction: 91% of intact [ P = .001]; 60° of abduction: 55% of intact [ P = .04]) but did not inhibit glenohumeral superior translation. By adding posterior side-to-side sutures, both glenohumeral superior translation (0° of abduction: 93% of intact [ P = .02]; 30° of abduction: 110% of intact [ P = .04]) and subacromial peak contact pressure decreased significantly (0° of abduction: 56% of intact [ P = .0001]; 30° of abduction: 83% of intact [ P = .0003]; 60° of abduction: 46% of intact [ P = .04]). Neither SCR with nor SCR without side-to-side suturing ameliorated the tear-associated decrease in glenohumeral compression force and increase in total ROM. Adding anterior side-to-side sutures did not change any measurements compared with SCR with posterior side-to-side suturing. Conclusion: SCR with side-to-side suturing completely restored the superior stability of the shoulder joint by establishing posterior continuity between the graft, residual infraspinatus tendon, and underlying shoulder capsule. Clinical Relevance: Side-to-side suturing between the graft, residual infraspinatus tendon, and underlying shoulder capsule is recommended for SCR in patients with irreparable supraspinatus tendon tears to restore superior stability after surgery.

Publisher

SAGE Publications

Subject

Physical Therapy, Sports Therapy and Rehabilitation,Orthopedics and Sports Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3