High Failure Rate of a Decellularized Osteochondral Allograft for the Treatment of Cartilage Lesions

Author:

Farr Jack1,Gracitelli Guilherme C.2,Shah Nehal3,Chang Eric Y.4,Gomoll Andreas H.3

Affiliation:

1. Cartilage Restoration Center of Indiana, OrthoIndy Hospital, Indianapolis, Indiana, USA

2. Department of Orthopaedic Surgery, Federal University of São Paulo, São Paulo, Brazil

3. Brigham and Women’s Hospital, Harvard Medical School, Boston, Massachusetts, USA

4. Radiology Service, VA San Diego Healthcare System, San Diego, California, USA

Abstract

Background: Widespread adoption of fresh allograft transplantation remains limited, predominantly by supply issues. To overcome these limitations, a preshaped, cylindrical sterilized and decellularized osteochondral allograft (SDOCA) implant was recently introduced as a clinical treatment option. Purpose: To evaluate functional outcomes and graft survivorship among patients treated with the SDOCA implant for knee cartilage injuries. Study Design: Case series; Level of evidence, 4. Methods: An institutional review board–approved database was used to identify a series of patients with prospectively collected data who had been treated with the SDOCA implant. The surgeries were performed at 2 centers by 2 surgeons. Patient-reported outcomes, magnetic resonance imaging (MRI), and the number and type of reoperations were assessed. Failure was defined as structural damage of the graft diagnosed by arthroscopy or MRI, and any reoperation resulting in removal of the allograft. Patients were evaluated pre- and postoperatively using the Knee injury and Osteoarthritis Outcome Score (KOOS) and Marx Sports Activity Scale. MRI was assessed preoperatively and postoperatively. Results: There were 32 patients with a mean age (±SD) of 35.1 ± 10.6 years; 59% were male. Twenty-three (72%) knees had previous surgery. The mean defect area (±SD) was 2.9 ± 2.0 cm2, and the mean allograft size was 13.18 ± 2.3 mm (6 grafts ≤9 mm and 59 grafts ≥11 mm). The median number of allografts per knee was 2 (range, 1-5 grafts). Twenty-three of the 32 knees (72%) were considered failures by the definition detailed above. Of these, 14 knees (43%) had further surgery after the index procedure. Implant survivorship was 19.6% at 2 years. The mean follow-up duration was 1.29 years (range, 0.11-2.8 years). KOOS pain, activities of daily living (ADL), sports and recreation (sport/rec), and knee-related quality of life improved significantly from the preoperative visit to latest follow-up. Age was significantly predictive of failure, with a hazard ratio of 1.68 per 1 SD older (95% CI, 1.05-2.68; P = .030). The MOCART (magnetic resonance observation of cartilage repair tissue) feature effusion was the only score to correlate with KOOS (symptoms, pain, ADL, sport/rec). Conclusion: The SDOCA implant demonstrated a 72% failure rate within the first 2 years of implantation at these 2 institutions.

Publisher

SAGE Publications

Subject

Physical Therapy, Sports Therapy and Rehabilitation,Orthopedics and Sports Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3