Abstract

Background: The outcome of rotator cuff repair correlates with tendon healing. Early studies of arthroscopic rotator cuff repair demonstrate lower healing rates than traditional open techniques. Transosseous-equivalent repair techniques (suture bridge) were developed to improve the initial fixation strength. Purpose: To compare the initial in vitro tensile fixation strength of a transosseous-equivalent suture bridge (TOE-SB) rotator cuff repair construct to a traditional transosseous (TO) suture construct. Study Design: Controlled laboratory study. Methods: Identical simulated rotator cuff tears were created on 8 matched pairs of humeri. Each matched pair underwent repair with 4 sutures using either the TOE-SB or TO technique. Initial fixation strength was tested in a custom testing jig. Each shoulder underwent 1000 cycles each of low and then high load testing. Gap displacement was measured at anterior and posterior sites of the repair with digital video tracking of paired reflective markers and recorded at predetermined cycle intervals. Results: There were no statistically significant differences in gap formation at the repair sites under low or high load conditions between TOE-SB and TO techniques. The mean maximal gap formation of the repairs during low load testing in the TOE-SB and TO constructs was 0.93 ± 0.88 mm and 0.55 ± 0.22 mm, respectively ( P = .505). The mean maximal gap formation during high load testing in the TOE-SB and TO constructs was 2.04 ± 1.10 mm and 2.28 ± 1.62 mm, respectively ( P = .517). The most significant increase in gap distance occurred at the transition from low load to high load in both constructs. Most of the incremental displacement occurred within the first 100 cycles for both high and low load testing ( P < .001). Conclusion: The arthroscopic TOE-SB technique is comparable in initial fixation strength to the traditional TO simple suture repair technique. Clinical Relevance: Arthroscopic techniques can achieve initial fixation strength comparable with traditional TO techniques performed without suture anchors.

Publisher

SAGE Publications

Subject

Physical Therapy, Sports Therapy and Rehabilitation,Orthopedics and Sports Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3