Background: Little is known about radial displacement (RD) of polyurethane (PU) scaffolds, intended for partial meniscus defect substitution; no data are available on whether rim thickness influences RD and whether RD correlates with clinical outcome scores. Hypotheses: The meniscus is not extruded preoperatively, but RD occurs after scaffold implantation. A thicker rim will limit RD, and there is no correlation between RD and clinical outcome. Study Design: Case series; Level of evidence, 4. Methods: Twenty-six patients were implanted with a PU scaffold (8 lateral, 18 medial). Radial displacement (mm) was evaluated on magnetic resonance images preoperatively and at 3 months, 1 year, and 2 years postoperatively. At each time point, it was determined whether a correlation existed between the rim and RD. Clinical outcome was determined using a visual analog scale (VAS) for pain as well as the Lysholm knee scoring scale, Knee Injury and Osteoarthritis Outcome Score (KOOS), and International Knee Documentation Committee (IKDC) score. Results: Radial displacement of lateral scaffolds was not significantly different ( P = .178) either preoperatively (mean ± SD, 3.42 ± 0.99 mm) or at 3 months (4.82 ± 0.59 mm), 1 year (4.55 ± 0.87 mm), or 2 years postoperatively (4.10 ± 0.93 mm). No correlation was observed between the rim and lateral RD at all time points. Medial scaffold RD increased significantly ( P < .001) from preoperative values (2.17 ± 0.84 mm) to those at 3 months (4.25 ± 0.89 mm), 1 year (4.43 ± 1.01 mm), and 2 years postoperatively (4.41 ± 0.96 mm). A strong negative correlation between medial RD and the rim was observed at all time points. There was no significant correlation between clinical outcome scores and RD, either preoperatively or postoperatively. Conclusion: This study demonstrated that limited medial meniscal RD was present preoperatively but increased by 2 mm after scaffold implantation. Lateral RD was also present preoperatively but did not increase after scaffold implantation. Importantly, a strong negative correlation was found between the rim and postoperative medial RD; a thicker rim limited RD. However, in the lateral compartment, rim thickness did not correlate with RD because RD was already strongly present preoperatively. Finally, no correlations were observed between scaffold RD and clinical outcome scores, either preoperatively or postoperatively.

Publisher

SAGE Publications

Subject

Physical Therapy, Sports Therapy and Rehabilitation,Orthopedics and Sports Medicine

Cited by 61 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3