Biomechanical Analysis of Chlorhexidine Power Irrigation to Disinfect Contaminated Anterior Cruciate Ligament Grafts

Author:

Han Yung1,Giannitsios Demetri2,Duke Kajsa3,Steffen Thomas2,Burman Mark1

Affiliation:

1. Department of Orthopaedic Surgery, McGill University, Montreal, Quebec, Canada

2. Orthopaedic Research Laboratory, McGill University, Montreal, Quebec, Canada

3. Department of Mechanical Engineering, University of Alberta, Edmonton, Alberta, Canada

Abstract

Background: Accidental graft contamination is a likely complication to occur in an orthopaedic sports medicine surgeon’s career. There are no clinical outcome studies to direct management, and a recent survey showed that preferred management varied. Three liters of 2% chlorhexidine power irrigation has been shown to be an efficient and effective disinfection protocol; however, the biomechanical sequelae of this disinfection protocol to the graft are unknown. Purpose: The purpose of this study was to determine if 3 L of 2% chlorhexidine power irrigation used to disinfect contaminated anterior cruciate ligament (ACL) grafts significantly weakens the graft at time zero. Study Design: Controlled laboratory study. Methods: Eight fresh bovine superficial digital flexor tendons underwent disinfection protocol with 3 L of 2% chlorhexidine power irrigation. Contralateral tendons served as the control. Tendons were preconditioned and loaded to failure. Results: The average ultimate failure load for the control tendons and disinfected tendons was 4081 ± 654.4 N and 4146 ± 723.2 N, respectively. The average ultimate failure stress for the control tendons and disinfected tendons was 97.10 ± 12.03 MPa and 95.18 ± 11.79 MPa, respectively. The average stiffness for the control tendons and disinfected tendons was 546.20 ± 28.16 N/mm and 539.2 ± 25.93 N/mm, respectively. The P values for ultimate failure load, ultimate failure stress, and stiffness showed no statistically significant difference between the chlorhexidine and control tendons. Conclusion: Disinfecting tendons with 3 L of 2% chlorhexidine power irrigation does not adversely weaken the tendon’s tensile mechanical properties. Clinical Relevance: Three liters of 2% chlorhexidine power irrigation can effectively disinfect a contaminated ACL graft without weakening the graft.

Publisher

SAGE Publications

Subject

Physical Therapy, Sports Therapy and Rehabilitation,Orthopedics and Sports Medicine

Cited by 12 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3