Accuracy of Computer Navigation–Assisted Arthroscopic Osteochondroplasty for Cam-Type Femoroacetabular Impingement Using the Model-to-Image Registration Method

Author:

Abe Koki1ORCID,Oba Masatoshi1,Kobayashi Naomi2ORCID,Higashihira Shota1ORCID,Choe Hyonmin1,Tezuka Taro1,Ike Hiroyuki1,Inaba Yutaka1

Affiliation:

1. Department of Orthopedic Surgery, Yokohama City University, Yokohama, Japan

2. Department of Orthopedic Surgery, Yokohama City University Medical Center, Yokohama, Japan

Abstract

Background: Precise osteochondroplasty is important in arthroscopic hip surgery for cam-type femoroacetabular impingement (FAI). Although computer-assisted surgery with a navigation system may enhance the accuracy of arthroscopic osteochondroplasty, few clinical studies have assessed its accuracy. Purpose: To evaluate the accuracy of arthroscopic osteochondroplasty by a computed tomography (CT)–based navigation system for cam-type FAI, using 3-dimensional (3D) reconstruction with more detail compared with previous methods. Study design: Case series; Level of evidence, 4. Methods: Twenty patients (14 men and 6 women) who underwent navigation-assisted arthroscopic surgery for cam-type FAI were included. The preoperative 3D model of the femur was constructed from each patient’s CT data, and a planned model with virtual cam resection was generated. A femoral model was reconstructed from CT data postoperatively. The 3 models for each patient were overlaid using a 3D model registration method. Then, the contours of the bone resection area of each model were compared by measuring them. To measure the deviation between planned and actual bone resections, 4 cross-sectional images of the 3 femoral models were set at one-quarter intervals from the femoral head radius. All measurements were based on clockface lines set around the femoral neck axis at 30-minute intervals. Differences between the planned and postoperative contour lines were deemed resection deviations. Results: All cam resections were performed in the anterior half of the region of interest. Therefore, only the anterior half (48 points) of the 96 points per case were analyzed. In 876 (91.3%) points of the total measurement points (960 points/20 cases), the error in resection depth was within 3 mm. Overresection was observed at 35 (3.6%) points and underresection at 49 (5.1%) points. The observed maximum deviations from the planned models were 6.3 mm overresection and –7.1 mm underresection. The alpha angles of the postoperative model at the posterior 9- to 3-o’clock position were <55° in all patients. Conclusion: Navigation-assisted arthroscopic osteochondroplasty showed favorable accuracy. Underresection was more frequent than overresection on the anterosuperior side of the femur, despite assistance of the navigation system.

Funder

Japan Society for the Promotion of Science

Publisher

SAGE Publications

Subject

Physical Therapy, Sports Therapy and Rehabilitation,Orthopedics and Sports Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3