Early experience with the GORE-TEX polytetrafluoroethylene anterior cruciate ligament prosthesis

Author:

Indelicato Peter A.1,Pascale Mark S.1,Huegel Marty O.1

Affiliation:

1. Department of Orthopaedics, University of Florida, Gainesville, Florida

Abstract

A prospective study of 41 patients with acute and chronic ACL deficiency underwent reconstruction with the GORE-TEX polytetrafluoroethylene (PTFE) ACL prosthesis beginning in November 1983. Thirty-nine patients who were at least 2 years from their surgical procedure were available for follow-up evaluation, which included subjective questionnaire, clinical exam ination, and instrumented ligamentous laxity tests. Eight patients had an acute injury to the ACL and 31 patients had chronic ACL insufficiency for which recon struction was performed. Thirty-four patients had satisfactory results, allowing full return to activity with no appreciable symptomatol ogy. Of the remaining five patients, four had a complete rupture of the prosthesis. The average knee arthrome tric measurement improved from a 5.4 mm left/right difference preoperatively to a 2.0 mm left/right differ ence at 2 year followup. Nine patients had postopera tive complications of one or more atraumatic episodes of a sterile effusion. Six patients had recurrent effu sions ; in five, arthroscopy revealed partial tears of less than one-third of the prosthesis. Three patients who had recurrent effusions had PTFE particles in their synovial biopsies. One patient had an immediate post operative infection and to date has had salvage of the prosthesis and currently has a stable knee with full return to activities. Based on the early results of this study, the GORE- TEX PTFE ACL prosthesis provided a satisfactory method of reconstruction for ACL deficient knees. Based on the evaluation used, 87% of the patients had satisfactory results. Problems associated with use of this prosthesis include partial or complete tears of the prosthesis and sterile effusions, possibly due to syno vial irritation from the PTFE particles. Appropriate placement of the graft, anterior and posterior notch plasty, and removal of sharp edges from the bony tunnels may help eliminate these problems.

Publisher

SAGE Publications

Subject

Physical Therapy, Sports Therapy and Rehabilitation,Orthopedics and Sports Medicine

Cited by 89 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3