Arthroscopic Transtendon Repair of Partial-Thickness Articular-Side Tears of the Rotator Cuff

Author:

Ide Junji1,Maeda Satoshi1,Takagi Katsumasa1

Affiliation:

1. Department of Orthopaedic Surgery, Kumamoto University Hospital, Department of Orthopaedic Surgery, Graduate School of Medical Sciences, Kumamoto University, Kumamoto, Japan

Abstract

Background The precise results of arthroscopic transtendon repair of partial-thickness articular-side tears of the rotator cuff remain to be reported. Hypothesis Arthroscopic transtendon repair is useful in patients with Ellman grade 3 (>6 mm) partial-thickness articular-side tears of the supraspinatus tendon. Study Design Descriptive laboratory study and case series; Level of evidence, 4. Methods In 43 cadaveric shoulders (mean age, 80 years; range, 50-97 years), the authors measured the width of the supraspinatus insertion (medial-to-lateral direction) and the distance between the articular cartilage edge and the tendon insertion at a site 10 mm lateral to the anterior margin of the greater tuberosity. A clinical study group of 17 patients (mean age, 42 years; range, 17-51 years) was observed for a mean follow-up of 39 months (range, 25-57 months). University of California at Los Angeles and Japanese Orthopaedic Association shoulder scores and postoperative overhead athletic activities were evaluated. Results The mean width of the supraspinatus insertion was 9.6 mm (SD, 1.6 mm; range, 7-13 mm; 95% confidence interval, 9.1-10.1 mm; 95% prediction interval, 6.4-12.8 mm). The mean distance between the articular cartilage edge and the tendon insertion was 0.3 mm (range, 0-2 mm). After the procedure, the mean University of California at Los Angeles and Japanese Orthopaedic Association scores significantly improved from 17.3 and 68.4 points to 32.9 and 94.8 points, respectively (P <. 01). Rated on the Japanese Orthopaedic Association scale, results were excellent in 14, good in 2, and fair in 1 patient; there were no poor results. Of 6 overhead-throwing athletes, 2 returned to their previous sports at the same level, 3 returned at a lower level, and 1 was unable to return. Conclusion Arthroscopic transtendon repair is a safe, reliable procedure in patients with grade 3 partial-thickness articular-side tears. In the majority of patients, partial tears of more than 6 mm of the supraspinatus tendon thickness involved more than 50% of the entire tendon thickness.

Publisher

SAGE Publications

Subject

Physical Therapy, Sports Therapy and Rehabilitation,Orthopedics and Sports Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3