Perfusion of the Rotator Cuff Tendon According to the Repair Configuration Using an Indocyanine Green Fluorescence Arthroscope: A Preliminary Report

Author:

Kim Sae Hoon1,Cho Won-Sang2,Joung Ho-Yun1,Choi Young Eun1,Jung Minwoong3

Affiliation:

1. Department of Orthopaedic Surgery, Seoul National University Hospital, Seoul National University College of Medicine, Seoul, Korea

2. Department of Neurosurgery, Seoul National University Hospital, Seoul National University College of Medicine, Seoul, Korea

3. Russia Science Seoul Center, Korea Electrotechnology Research Institute, Seoul, Korea

Abstract

Background: The disturbance of rotator cuff tendon perfusion has been connected with the suture-bridge configuration repair (SBCR) technique; however, in vivo assessments of the tendon blood supply have been problematic with other modalities. An evaluation of tissue perfusion by an indocyanine green (ICG) fluorescence arthroscope has been developed to counteract this difficulty. Purpose: To verify the hindrance of perfusion in SBCR, we used an ICG fluorescence camera to compare parallel-type transosseous repair (PTR) and SBCR in rabbits immediately and at 3 days after rotator cuff repair. Study Design: Controlled laboratory study. Methods: Acute rotator cuff repair was performed on the shoulders of 10 rabbits. Both shoulders were repaired using either PTR or SBCR. For PTR, simple repair was performed through 2 parallel transosseous tunnels created using a microdrill. For SBCR, 2 additional crisscross transosseous tunnels were added to mimic arthroscopic SBCR. Immediately after repair, ICG was injected through the ear vein, and images were recorded using an ICG fluorescence camera. Tendon perfusion was compared by measuring fluorescence intensity using ImageJ software in both methods. At 3 days after rotator cuff repair, a reassessment of ICG fluorescence was performed. In addition, as a subsidiary study, a comparison of each repair method and a healthy tendon was performed (PTR vs healthy tendon and SBCR vs healthy tendon). Six rabbits (3 for each comparison) were included. Results: Immediately after rotator cuff repair, the mean (±SD) grayscale intensity of ICG fluorescence was weaker in SBCR than PTR in 10 specimens (65.9 ± 47.6 vs 84.3 ± 53.4 per pixel, respectively; P = .003). At 3 days after repair, 8 specimens were included in the analysis because suture strands failed in 2 specimens in SBCR. The mean intensity of fluorescence was still weaker in SBCR compared with PTR (52.5 ± 13.7 vs 60.2 ± 22.7 per pixel, respectively; P = .077). The mean fluorescence intensity compared with a healthy tendon was 83.2% ± 9.5% in PTR and 63.2% ± 13.2% in SBCR. Conclusion: Our ICG fluorescence camera system was able to detect ICG fluorescence in an acute rabbit rotator cuff repair model. SBCR showed inferior tendon perfusion immediately after repair. At 3 days after repair, SBCR still showed inferior fluorescence intensity, although it did not reach statistical significance. Clinical Relevance: In this study, SBCR hindered perfusion at the tendon in the compressed area. This finding may affect rotator cuff tendon healing and failure mode.

Publisher

SAGE Publications

Subject

Physical Therapy, Sports Therapy and Rehabilitation,Orthopedics and Sports Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3