Abstract

Background: Suture-button fixation for tibiofibular syndesmosis injuries is a relatively new surgical technique thought to provide semirigid dynamic stabilization. However, adequate information is still not available and there are controversies as to whether it provides enough fixation for syndesmosis injuries. Hypothesis: Optimally directed suture-button fixation brings physiologic dynamic stabilization of the ankle syndesmosis. Study Design: Controlled laboratory study. Methods: Stabilization of the ankle syndesmosis fixed by a suture-button construct was examined using 6 normal fresh-frozen cadaver legs. After initial tests of intact and injured models, suture-button fixation and screw surgical techniques were performed sequentially for each specimen, with single suture-button fixation, double suture-button fixation, anatomic suture-button fixation, and metal screw. Anterior and medial traction forces, as well as external rotation force, were applied to the tibia; the diastasis of the syndesmosis and the rotational angle of the fibula related to the tibia were measured using a magnetic tracking system. Results: Each traction and rotation force significantly increased the diastasis and fibular rotational angles in the created injury models. With single fixation, the diastases increased significantly compared with the intact model with an anterior traction force ( P < .001), a medial traction force ( P = .005), and an external rotation force ( P = .015). The fibular rotational angles increased significantly with a medial traction force ( P = .005) and an external rotation force ( P < .001). With double fixation, the diastases increased significantly with a medial traction force ( P = .004) and an external rotation force ( P = .012). The fibular rotational angles increased significantly with a medial traction force ( P = .035) and an external rotation force ( P = .002). With anatomic fixation, there were no significant differences compared with the intact model. With the metal screw, the diastases decreased significantly with an external rotation force ( P = .037). Conclusion: Neither single nor double fixation for syndesmosis injuries provided multidirectionally stabilizing syndesmosis. Anatomic fixation directed from the posterior cortex of the fibula to the anterolateral edge of the tibia allowed dynamic stabilization of intact cadaver specimens. The metal screw provided very rigid fixation. Clinical Relevance: Optimal direction of the suture button can provide adequate stabilization of the ankle and could benefit athletes with syndesmosis injuries.

Publisher

SAGE Publications

Subject

Physical Therapy, Sports Therapy and Rehabilitation,Orthopedics and Sports Medicine

Cited by 92 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3