A Biomechanical Comparison of Fifth Metatarsal Jones Fracture Fixation Methods

Author:

Duplantier Neil L.1,Mitchell Ronald J.1,Zambrano Steve2,Stone Aaron C.2,Delgado Domenica A.1,Lambert Bradley S.12,Moreno Michael R.12,Harris Joshua D.1,McCulloch Patrick C.1,Lintner David M.1,Varner Kevin E.1

Affiliation:

1. Houston Methodist Hospital, Orthopedics & Sports Medicine, Houston, Texas, USA

2. Department of Biomedical Engineering, Texas A&M University, College Station, Texas, USA

Abstract

Background: Fifth metatarsal base fractures of the metaphyseal-diaphyseal watershed junction (Jones fracture) are commonly treated with surgical fixation in athletes. Intramedullary screw fixation remains the most utilized construct, although plantar-lateral plating is an alternative. Purpose/Hypothesis: The purpose was to compare the mechanical strength of fracture fixation between an intramedullary screw and plantar-lateral plating. The hypothesis was that plantar-lateral plate fixation would allow for more cycles and higher peak loads before failure, as well as less fracture gapping, than would an intramedullary screw in cadaveric foot specimens with simulated Jones fractures exposed to cantilever bending. Study Design: Controlled laboratory study. Methods: Twelve pairs of male cadaver feet were separated into 2 groups (plate or screw) to conduct contralateral comparative testing of 2 devices with equally numbered right and left feet. For each fifth metatarsal, an osteotomy with a microsagittal saw was created to simulate a Jones fracture. The plate group underwent fixation with a 3.0-mm 4-hole low-profile titanium plate placed plantar-laterally with 3 locking screws and 1 nonlocking screw. The screw group underwent fixation with a 40- or 45-mm × 5.5-mm partially threaded solid titanium intramedullary screw. After fixation, the metatarsals were excised for biomechanical testing. Cyclic cantilever failure testing was conducted with a gradient-cycle method. Sinusoidal loading forces were applied, increasing by 5.0-pound-force increments per 10 cycles, until each specimen experienced mechanical failure of implant or bone. Failure mode, number of cycles to failure, peak failure load, gap width at the last mutual prefailure loading, and video data were recorded. Paired 2-tailed t test (α = 0.05) was used to compare groups ( P < .05 set for significance). Results: Failure mode in both groups occurred predominantly at the bone-implant interface. Plate fixation resulted in significantly higher mean ± SD values for cycles to failure (63.9 ± 27.0 vs 37.3 ± 36.9, P = .01) and peak failure load (159.2 ± 60.5 N vs 96.5 ± 45.8 N, P = .01), with a significantly lower mean gap width (0.0 ± 0.0 mm vs 3.2 ± 2.4 mm, P < .01). Conclusion: As compared with intramedullary screw fixation, plantar-lateral plating allowed for greater cycles to failure and peak load before failure, as well as less gap width, when applied to cadaver foot specimens with simulated Jones fractures exposed to cantilever bending in a load frame. Clinical Relevance: Early return to play among athletes before Jones fracture union is associated with increased risk of failure. This study introduces a plantar-lateral plating construct that performed more favorably than intramedullary screw fixation when applied to simulated Jones fractures in cadaveric foot specimens. Further clinical comparative studies are needed to assess the clinical use of this construct.

Publisher

SAGE Publications

Subject

Physical Therapy, Sports Therapy and Rehabilitation,Orthopedics and Sports Medicine

Cited by 42 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Fifth Metatarsal Fractures;Clinics in Podiatric Medicine and Surgery;2024-07

2. Fractures des métatarsiens sans atteinte du Lisfranc;Revue de Chirurgie Orthopédique et Traumatologique;2024-07

3. Stress fractures of the foot - current evidence on management;Journal of Clinical Orthopaedics and Trauma;2024-03

4. Compression screw internal fixation versus non-weight-bearing cast immobilization for Jones fractures in children;Injury;2024-02

5. Acute and stress fractures of the metatarsals in athletes;Orthopaedics and Trauma;2024-02

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3