The effect of continuous passive motion on anterior cruciate ligament reconstruction stability

Author:

Burks Robert1,Daniel Dale1,Losse Gary1

Affiliation:

1. Department of Orthopedic Surgery, Kaiser Hospital, and The Division of Orthopedic Surgery, University of California at San Diego, San Diego, California

Abstract

This study was undertaken to examine the immediate effect of continuous passive motion (CPM) on anterior cruciate ligament (ACL) reconstruction stability. Ca daver knees were tested with a knee arthrometer with the anterior cruciate intact and then with the anterior cruciate sectioned. One of three anterior cruciate re constructions was then performed and stability was restored to the knee and it was again tested with the knee arthrometer. Stability was defined as being within 2 mm of the intact measurement. The three operations selected were the Marshall-Maclntosh "over-the-top," (OTT) a patellar bone-patellar tendon-tubercle bone (BTB) graft, and a semitendinosis reconstruction. The specimens were placed on a CPM device in a cooler at 38°F and put through a range of motion of 20 to 70° at 10 cycles per minute for 3 days. A success was less than a 2 mm increase in the post-CPM measurement compared to pre-CPM. All three bone-tendon-bone op erations failed. The semitendinosis operation was suc cessful in only three out of eight specimens. The OTT operation was successful in eight out of nine speci mens. The possible reasons for success and failure are discussed. Because of the potential problems with failure of an ACL with CPM it is suggested that the particular tech nique being used for an anterior cruciate reconstruction be tested prior to it being used with CPM clinically.

Publisher

SAGE Publications

Subject

Physical Therapy, Sports Therapy and Rehabilitation,Orthopedics and Sports Medicine

Reference8 articles.

1. Grood ES, Hefzy MS, Butler DL, et al On the placement and the initial tension of anterior cruciate ligament substitutes Trans Orthop Res 8 92, 1983

2. Lambert KL Vascularized patellar tendon graft with rigid internal fixation for anterior cruciate ligament insufficiency Clin Orthop 172. 85-89, 1983

3. Malcolm LL, Daniel D., Schwab G. The clinical measurement of sagittal plane tibio-femoral translocation Trans Orthop Res Soc 7 253, 1982

4. Marshall JL, Warren RF, Wickiewicz et al. The anterior cruciate ligament: A technique of repair and reconstruction. Clin Orthop 143 97, 1979

5. Mott HW Semitendinosus anatomic reconstruction for cruciate ligament insufficiency Clin Orthop 172: 90-92, 1983