Size Variability of the Human Anterior Cruciate Ligament Insertion Sites

Author:

Kopf Sebastian1,Pombo Mathew W.1,Szczodry Michal1,Irrgang James J.1,Fu Freddie H.1

Affiliation:

1. Department of Orthopaedic Surgery, University of Pittsburgh, Pittsburgh, Pennsylvania.

Abstract

Background: Current trends in anterior cruciate ligament reconstruction (ACLR) have been toward anatomical reconstruction that restores the normal size and location of the anterior cruciate ligament insertions and its 2 bundles, the posterolateral (PL) and anteromedial (AM) bundles. This has resulted in a more individualized approach to ACLR. Several studies have shown that the size of the anterior cruciate ligament insertion sites is variable; however, these studies are limited by use of relatively small sample sizes and cadaveric specimens. Purpose: This study was undertaken to evaluate the in vivo size variability of the anterior cruciate ligament insertion sites and its AM and PL bundles during arthroscopy in a large series of patients and to correlate these findings with individuals’ physical characteristics (height, weight, and body mass index). Study Design: Cross-sectional study; Level of evidence, 3. Methods: In 137 patients undergoing ACLR during the first 6 months after injury, the femoral and tibial anterior cruciate ligament insertion sites and the 2 bundles were identified, marked with electrocautery, and measured with an arthroscopic ruler. Additionally, physical characteristics of the patients, including self-reported height, weight, and body mass index, were recorded. Results: The tibial anterior cruciate ligament insertion site had a mean length of 17.0 ± 2.0 mm. The tibial AM bundle length was 9.1 ± 1.2 mm and the width was 9.2 ± 1.1 mm. The tibial PL bundle insertion site length averaged 7.4± 1.0 mm and the width averaged 7.0 ± 1.0 mm. The femoral insertion sites had a mean length of 16.5 ± 2.0 mm. The length of the femoral AM bundle insertion site averaged 9.2 ± 1.2 mm and the width averaged 8.9 ± 0.9 mm. The femoral PL bundle insertion site length averaged 7.1 ± 1.1 mm and the width averaged 6.9 ± 1.0 mm. There were significant positive correlations between patient height and weight ( P < .05) with femoral and tibial anterior cruciate ligament insertion site length, tibial PL bundle insertion site length, femoral AM bundle insertion site length, and tibial AM bundle and PL bundle insertion site areas. However, the coefficients of determination values were low (1.0% to 19.4%). Conclusion: There is a large variation in size of the anterior cruciate ligament insertion sites and the AM and PL bundles. Additionally, there are significant but weak correlations between the size of the insertions and height, weight, and body mass index of the individual patient.

Publisher

SAGE Publications

Subject

Physical Therapy, Sports Therapy and Rehabilitation,Orthopedics and Sports Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3