Abstract

Background Recently, there is increasing interest in different arthroscopic biceps tenodesis techniques. However, little data have been published about the biomechanical properties of soft tissue tenodesis. Purpose This study was undertaken to evaluate the biomechanical properties of 2 different arthroscopic biceps tenodeses: the percutaneous intra-articular transtendon (PITT) technique and the suture-anchor technique. Study Design Controlled laboratory study. Methods Fifteen fresh-frozen cadaveric specimens were randomly allocated to the 2 different biceps tenodesis techniques. The humerus with biceps tenodesis was mounted on a materials testing machine to perform a load to failure test. The structural properties including ultimate load (N) and stiffness (N/mm) were derived from the load-displacement curve. The mode of failure was also recorded. Ultimate load and stiffness were compared with the parametric Student t test. Results Both repairs showed typical load-displacement curves followed by a constant increase in load and displacement until failure occurred. Suture-anchor and PITT techniques had ultimate loads of 175.4 ± 40.4 N and 142.7 ± 30.9 N (P = .10) and stiffness of 15.9 ± 8.4 N/mm and 13.3 ± 3 N/mm (P = .36), respectively, with no significant differences between them. All of the surgical constructs failed in the tendon site by pulling out with the sutures through the substance of the tendon. Conclusion The suture-anchor and PITT techniques exhibited satisfactory initial strength with no statistical difference between the 2 groups. These findings, along with the consistent pullout of the suture through the tendon during failure, suggest that the most important factor for initial strength is not the attachment site but the quality of the biceps tendon. Clinical Relevance The quality of the tendon should be taken into account when deciding the surgical technique and the rehabilitation program. The PITT technique has the benefit of avoiding hardware complications and cost.

Publisher

SAGE Publications

Subject

Physical Therapy, Sports Therapy and Rehabilitation,Orthopedics and Sports Medicine

Cited by 40 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3