Intratendinous Strain Variations of the Supraspinatus Tendon Depending on Repair Technique: A Biomechanical Analysis Regarding the Cause of Medial Cuff Failure

Author:

Hackl Michael12,Nacov Julia12,Kammerlohr Sandra12,Staat Manfred3,Buess Eduard4,Leschinger Tim12,Müller Lars P.12,Wegmann Kilian12

Affiliation:

1. University of Cologne, Faculty of Medicine, Cologne, Germany

2. University Hospital Cologne, Center of Orthopedic and Trauma Surgery, Cologne, Germany

3. Institute of Bioengineering, FH Aachen University of Applied Sciences, Jülich, Germany

4. Shouldercare, Engeriedspital, Bern, Switzerland

Abstract

Background: Double-row (DR) and transosseous-equivalent (TOE) techniques for rotator cuff repair offer more stability and promote better tendon healing compared with single-row (SR) repairs and are preferred by many surgeons. However, they can lead to more disastrous retear patterns with failure at the medial anchor row or the musculotendinous junction. The biomechanics of medial cuff failure have not been thoroughly investigated thus far. Purpose: To investigate the intratendinous strain distribution within the supraspinatus tendon depending on repair technique. Study Design: Controlled laboratory study. Methods: Twelve fresh-frozen cadaveric shoulders were used. The intratendinous strain within the supraspinatus tendon was analyzed in 2 regions—(1) at the footprint at the greater tuberosity and (2) medial to the footprint up to the musculotendinous junction—using a high-resolution 3-dimensional camera system. Testing was performed at submaximal loads of 40 N, 60 N, and 80 N for intact tendons, after SR repair, after DR repair, and after TOE repair. Results: The tendon strain of the SR group differed significantly in both regions from that of the intact tendons and the TOE group at 40 N ( P≤ .043) and from the intact tendons, the DR group, and the TOE group at 60 N and 80 N ( P≤ .048). SR repairs showed more tendon elongation at the footprint and less elongation medial to the footprint. DR and TOE repairs did not provide significant differences in tendon strain when compared with the intact tendons. However, the increase in tendon strain medial to the footprint from 40 N to 80 N was significantly more pronounced in the DR and TOE group ( P≤ .029). Conclusion: While DR and TOE repair techniques more closely reproduced the strains of the supraspinatus tendon than did SR repair in a cadaveric model, they showed a significantly increased tendon strain at the musculotendinous junction with higher loads in comparison with the intact tendon. Clinical Relevance: DR and TOE rotator cuff reconstructions lead to a more anatomic tendon repair. However, their use has to be carefully evaluated whenever tendon quality is diminished, as they lead to a more drastic increase in tendon strain medial to the footprint, putting these repairs at risk of medial cuff failure.

Publisher

SAGE Publications

Subject

Physical Therapy, Sports Therapy and Rehabilitation,Orthopedics and Sports Medicine

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3