Complications of Bioabsorbable Suture Anchors in the Shoulder

Author:

Dhawan Aman1,Ghodadra Neil1,Karas Vasili1,Salata Michael J.2,Cole Brian J.1

Affiliation:

1. Rush University Medical Center, Chicago, Illinois

2. University Hospitals Case Medical Center, Cleveland, Ohio

Abstract

The development of the suture anchor has played a pivotal role in the transition from open to arthroscopic techniques of the shoulder. Various suture anchors have been manufactured that help facilitate the ability to create a soft tissue to bone repair. Because of reported complications of loosening, migration, and chondral injury with metallic anchors, bioabsorbable anchors have become increasingly used among orthopaedic surgeons. In this review, the authors sought to evaluate complications associated with bioabsorbable anchors in or about the shoulder and understand these in the context of the total number of bioabsorbable anchors placed. In 2008, 10 bioabsorbable anchor–related complications were reported to the US Food and Drug Administration. The reported literature complications of bioabsorbable anchors implanted about the shoulder include glenoid osteolysis, synovitis, and chondrolysis. These potential complications should be kept in mind when forming a differential diagnosis in a patient in whom a bioabsorbable anchor has been previously used. These literature reports, which amount to but a fraction of the total bioabsorbable anchors implanted in the shoulder on a yearly basis, underscore the relative safety and successful clinical results with use of bioabsorbable suture anchors. Product development continues with newer composites such as PEEK (polyetheretherketone) and calcium ceramics (tricalcium phosphate) in an effort to hypothetically create a mechanically stable construct with and improve biocompatibility of the implant. Bioabsorbable anchors remain a safe, reproducible, and consistent implant to secure soft tissue to bone in and about the shoulder. Meticulous insertion technique must be followed in using bioabsorbable anchors and may obviate many of the reported complications found in the literature. The purpose of this review is to provide an overview of the existing literature as it relates to the rare complications seen with use of bioabsorbable suture anchors in the shoulder.

Publisher

SAGE Publications

Subject

Physical Therapy, Sports Therapy and Rehabilitation,Orthopedics and Sports Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3